Weber 41995 manual Gas line to manifold connections Burner gas line connection

Models: 41995

1 60
Download 60 pages 45.83 Kb
Page 36
Image 36

 

Gas

Instructions

 

Check:

 

 

1)

Hose connection.

 

 

2)

Gas line to manifold connections.

(2)

(1)

3)

I.R. Burner gas line connection.

 

(3)

 

WARNING: If there is a leak at connection (1,2, or 3),

 

 

retighten the fitting with a wrench and recheck for

 

 

leaks with soap and water solution.

 

 

If a leak persists after re-tightening the fitting, turn OFF

 

the gas. DO NOT OPERATE THE GRILL. Contact the

 

Customer Service Representative in your region using

 

the contact information sheet provided with your

 

 

manual.

 

 

4)

Side burner hose to manifold connection

 

 

5)

Side burner hose to side burner connection

 

(4)

6)

Regulator to cylinder connection.

 

 

7)

Hose to regulator connection.

 

 

8)

Valves to manifold connections.

 

 

 

WARNING: If there is a leak at connections (4,5,6,7,

 

or 8), turn OFF the gas. DO NOT OPERATE THE GRILL.

 

Contact the Customer Service Representative in your

(5)

region using the contact information sheet provided

with your manual.

 

 

When leak checks are complete, turn gas supply OFF at

 

the source and rinse connections with water.

 

(8)

(2)(1)

(3)

(7)(6)

(4)

(5)

(8)

(7)(6)

C-5

Page 36
Image 36
Weber 41995 manual Gas line to manifold connections Burner gas line connection, Valves to manifold connections