Burner does not light.

Did you hold the burner control

Try to relight burner by holding

 

knob down and hold down for 20

burner control knob down and

 

seconds until after burner ignited?

continue holding down until 20

 

 

seconds after burner has ignited.

 

 

 

 

Did you wait to see the entire

When relighting burner by holding

 

ceramic surface become alight

burner control knob down, wait to

 

before counting 20 seconds?

see the entire ceramic surface

 

 

become alight before counting 20

 

 

seconds?

 

 

 

 

Is the igniter sparking?

Replace battery in igniter button

 

 

module.

 

 

Reseat burner ring.

 

 

 

Burner does not light or burner

The excess flow safety device,

Too reset the excess flow safety

has a small flickering flame.

which is part of the grill to cylinder

device turn all burner control knobs

 

connection, may have activated.

and the cylinder valve OFF.

 

 

Disconnect the regulator from the

 

 

cylinder. Turn burner control knobs

 

 

to HIGH. Wait at least 1 minute. Turn

 

 

burner control knobs OFF.

 

 

Reconnect the regulator to the

 

 

cylinder. Turn cylinder valve on

 

 

slowly. Refer to “Lighting

 

 

Instructions”

 

 

 

If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your region using the contact information sheet provided with your manual.