Operating Instructions

Lighting the Rotisserie Burner

ATTENTION: READ BEFORE

1

 

LIGHTING ROTISSERIE BURNER

 

After a period of non-use, before lighting the Rotis-

 

serie Burner, a few seconds must pass for the gas

 

supply line to fill.

 

When holding the ignition button you will see a flash

 

of flames moving from right to left across the Rotis-

8

serie Burner surface, the Rotisserie Burner is not lit

 

until the entire ceramic surface is aflame.

 

At this point, start a count of 20 seconds before

 

releasing the Rotisserie Burner control knob.

3

The Rotisserie Burner surface will glow red once the

4

burner is fully ignited.

6

 

3

CAUTION: The Rotisserie Burner flame may be

5,7

difficult to see on a bright sunny day.

 

WARNING: Check hose before each use of grill for

 

 

nicks, cracking, abrasions or cuts. If the hose is

1

 

found to be damaged in any way, do not use the

 

 

grill. Replace using only a Weber® authorized re-

 

 

placement hose. Contact the Customer Service

 

 

Representative in your region using the contact

 

 

information sheet provided with your manual.

 

 

1) Open the lid.

 

 

2) Remove the warming rack and the cooking grates

 

 

from the cookbox.

 

8

DANGER:

 

 

Failure to open the lid while igniting the grill, or not

 

 

waiting 5 minutes to allow the gas to clear if the grill

3

 

does not light, may result in an explosive flare-up

 

6

4

which can cause serious bodily injury or death.

 

3) Make sure all burner control knobs are turned OFF.

3

 

(Push control knob down and turn clockwise to ensure

 

5,7

 

that it is in the OFF position.)

 

 

WARNING: The burner control knobs must be in the

*The grill illustrated may have slight differences than the

OFF position before turning on the liquid propane

cylinder tank valve. If they are not in the OFF posi-

model purchased.

 

tion, when you turn on the LP cylinder valve, the

 

 

“excess gas flow control” feature will activate,

DANGER:

 

limiting the flow of gas from the LP cylinder. If this

When the “excess gas flow control” feature is acti-

should occur, turn OFF the LP cylinder valve and

vated, a small amount of gas is still flowing to the

burner control knobs. Then start over.

burners. After turning OFF the cylinder and burner

 

control knobs, wait at least 5 minutes for the gas to

 

clear before attempting to light the grill. Failure to do

 

so may result in an explosive flare-up, which can

 

cause serious bodily injury or death.

 

 

4) Turn the cylinder on by turning the cylinder valve

 

counterclockwise.

 

D-11

Page 50
Image 50
Weber 41995 manual Lighting the Rotisserie Burner, Lighting Rotisserie Burner