d)Unlatch the Spider Stopper Guards and remove. Figure 9.

Figure 9

e)Remove the manifold bracket and unscrew the two wing nuts that hold the manifold to the cooking box. Pull the manifold and valve assembly out of the burners and carefully set it down. Figure 10.

View from behind cooking box

Wing nuts

Figure 10

f)Slide the burner assembly out from under the guide screw and washer in the corners of the cooking box. Figure 11.

Guide screw

Figure 11

g)Lift and twist the burner assembly slightly, to separate the crossover tube from the burners. Figure 12. Remove the burners from the cooking box.

Crossover tube

Figure 12

h) To reinstall the burners, reverse steps c) through g).

mCAUTION: The burner openings must be positioned properly over the valve orifices. Figure 13a.

Check proper assembly before fastening manifold in place. Figure 13b.

(a)

Valve

Burner

(b)

Figure 13

24

Page 24
Image 24
Weber 500 LX owner manual To reinstall the burners, reverse steps c through g