Wells F-556 INSTALLATION continued, Warning Electric Shock Hazard, Fryer Electrical Installation

Models: F-856 F-556 F-676

1 14
Download 14 pages 29.29 Kb
Page 7
Image 7
INSTALLATION (continued)

INSTALLATION (continued)

WARNING: ELECTRIC SHOCK HAZARD

All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician.

DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock.

M303 p/n 307590 OpManual Built-In Std Fryer

FRYER ELECTRICAL INSTALLATION

Fryers must be connected directly to an appropriately sized electric circuit. Conduit and strain relief must be provided by the electrician. Refer to equipment nameplate for voltage and amperage requirements.

If an equipment shutdown interface is required by local fire code, the flame sensor terminal block may be accessed by removing the back panel. Replace the jumper of the terminal block with wiring to a normally closed contact of the building fire management system.

DO NOT connect power to the flame sensor terminal block. Wiring and contacts must be capable of handling 30 amps.

F-676 and F-856 fryers are shipped from the factory wired for three phase. Conversion to single phase must be performed in the field by the electrician.

CAUTION:

RISK OF

WARNING: ELECTRIC SHOCK HAZARDDAMAGE

DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.

CAUTION:

ELECTRIC FRYER ELECTRICAL INSTALLATIONELECTRIC SHOCK HAZARDSHOCK HAZARD

The ground lug of built-in fryers must be connected to a suitable building electric ground.

IMPORTANT: Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.

5

Page 7
Image 7
Wells F-556, F-676 INSTALLATION continued, Warning Electric Shock Hazard, Fryer Electrical Installation, Risk Of Damage