Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 29: Cathedral Ceiling Support Box
Installation.
STEP 6. Complete the cathedral ceiling installation by following the same procedures outlined in Steps 4 through 9 for INITIAL INSTALLATION
- VERTICAL INSTALLATION.
Figure 28: Cathedral Ceiling Support Box Leveling.
FREESTANDING DIRECT VENT KIT WITH COUPLER:
KIT COMPONENTS:
Quantity | Description | Quantity | Description | |
|
|
|
| |
1 | Horizontal direct vent termination cap | 1 | Ø65⁄8” (17 cm) 90° elbow | |
|
|
|
| |
2 | Flue collar adapters (only one used) | 4 | Wire spacers | |
|
|
|
| |
4 | 3 | Decorative rings | ||
|
|
|
| |
1 | Wall thimble | 1 | 4 oz tube RTV silicone | |
|
|
|
| |
1 | Inside finish trim collar | 20 | 9/16” tech screws | |
8 | 11⁄2” wood screws | 1 | Vinyl siding deflector | |
|
|
|
| |
1 | 5’ (190 cm) length of Ø4” (10 cm) | 2 | 24” (61 cm) section of Ø65⁄8” | |
double walled flex pipe | (17 cm) straight pipe | |||
|
| |||
|
|
|
|
Please ensure that all components are supplied with this kit. If components are missing or have been damaged, contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing or damaged.
INSTALLATION INSTRUCTIONS:
1.Decide on a location for the unit that will meet any or all local code requirements. Refer “Planning Your Installation” and “Clearances to Combustibles”.
2.Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the wall. If obstructions are found in the wall it may be necessary to adjust the location of the appliance.