20.Align all straight sections of pipe, slipping all joints together and installing with three (3) sheet metal screws evenly spaced.

21.Install the brass decorative rings around each joint making sure this decorative ring covers the sheet metal screws that secure each section of pipe together and secure to vent pipe in the slotted tab on the backside of the pipe so that the fastener would not be seen.

22.Secure the horizontal section of pipe to the inside finished collar by installing a screw in the tab on the inside finished collar. This will prevent the pipe from being disconnected at the vent terminal.

23.Light the appliance and ensure proper operation.

Wall thimble

Horizontal wall

fire stop

 

termination

 

Wall framing

Inside finished collar

 

Decorative

 

brass rings

 

Exhaust 4"

 

flex pipe

 

Combustion air

 

6 5/8" outer pipe

 

Flue pipe adaptor

 

for Westport

 

Figure 32: Assembly of Venting Kit.