Specifications
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
DIMENSIONS:
25 3⁄4"
(65.3cm)
27" |
(68.6cm) |
15 1/8"
(39.0cm)
27"
(68.5cm)
253⁄4"
(65.4cm)
15 3⁄4" (40.0cm)
171/8"
(43.5cm)
16 | 5/8" | Floor to center of flue | |
REAR VENT | |||
(42.2cm) | |||
231⁄2” (59.7 cm) | |||
|
| ||
25 3⁄4" |
|
| |
(65.3cm) |
|
|
Figure 1: Westport Exterior Dimensions.
CLEARANCES TO COMBUSTIBLES:
A. Sidewall to unit | 11 inches | (27.9 cm) |
B. Backwall to unit | 2.5 inches | (6.35 cm) |
C. Corner to unit | 2.5 inches | (6.35 cm) |
D. Ceiling | 60 inches above floor (152.4 cm) | |
E. Floor | (hard wood and linoleum) 0 inches |
Note: When installing on a carpeted surfaces a non- combustible hearth pad must be used.
Minimum Alcove Dimensions:
Width | 48 inches (121.9 cm) |
Height | 60 inches (152.4 cm) |
Depth (max) | 24 inches (60.96 cm) |
|
| ���� ���� | �������� ���� |
|
| � | |
���� ���� |
| � | |
|
| ||
� |
| � | |
|
| ||
| ����� | ������������ | |
|
|
Figure 2: Clearances to combustibles.
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE
5