Enviro C-10794 owner manual Initial Installation, Qualified Installers Only

Models: C-10794

1 45
Download 45 pages 19.59 Kb
Page 17
Image 17
Figure 20: Installing Horizontal Vent Termination.

Initial Installation

QUALIFIED INSTALLERS ONLY

every 36 inches (915 mm). Wall straps are available for this purpose, also when running horizontal pipe minimum clearances to combustibles must be maintained; 2 inches (51 mm) at top, 11⁄2 inches (38 mm) at sides, 11⁄2 inches (38 mm) at bottom.

STEP 3. With the pipe attached to the stove in the correct location, mark the wall for a 10” (25.4 cm) x 10” (25.4 cm) square hole (refer to Figure 17). The center of the square hole should match the center line of the horizontal pipe. Cut and frame the 10” (25.4 cm) x 10” (25.4 cm) hole in the exterior wall where the vent will be terminated. Refer to Figure 8. If the wall being penetrated is constructed of non-combustible material i.e. masonry or concrete, a 7 inches (17.8 cm) hole is acceptable.

STEP 4. Position the horizontal vent termination in the center of the 10” (25.4 cm) x 10” (25.4 cm) hole,

and attach to the exterior wall with the four screws provided. Before attaching the vent termination to the exterior wall, run a bead of non-hardening mastic around the edges, so as to make a seal between the termination and the wall. The arrow on the vent termination should be pointing up, insure that the proper clearances to combustible materials are maintained.

STEP 5. Before connecting the horizontal run of the vent pipe to the vent termination, slide the black decorative wall thimble cover over the vent pipe.

STEP 6. Slide the appliance and vent assembly towards the wall, carefully inserting the vent pipe into the cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a minimum of 11⁄4” (3.2 cm) overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the straps to the vent pipe. Bend any remaining portion of the sheet metal straps back towards the vent cap, so the decorative wall thimble will conceal it (see left image in Figure 18).

STEP 7. Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass or chrome trim if desired (see right image in Figure 18).

Figure 19: Installing Vent Cap with Vinyl Siding Stand-

Off.

Figure 20: Installing Horizontal Vent Termination.

17

Page 17
Image 17
Enviro C-10794 owner manual Initial Installation, Qualified Installers Only, Installing Horizontal Vent Termination