Enviro C-10794 owner manual Initial Installation, Qualified Installers Only

Models: C-10794

1 45
Download 45 pages 19.59 Kb
Page 13
Image 13
This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

Initial Installation

QUALIFIED INSTALLERS ONLY

VENT PARTS:

Table 3: Vent Pipe Types with Part Numbers.

Simpson Duravent (SD), Selkirk (SEL), and Security Chimneys (SC), must state if galvanized or black wanted, PART NUMBERS:

SD

SEL

SC

Description

SD

SEL

SC

Description

 

 

 

 

 

 

 

 

908

4DT-6

SV4L6

6” pipe length

911

 

 

11” to 14 5/8” pipe, adjustable

907

4DT-9

 

9” pipe length

 

4DT-AJ

 

4” to 10” pipe , adjustable

 

 

 

 

 

 

 

 

906

4DT-12

SV4L12

12” pipe length

 

 

SV4LA12

11⁄2” to 12” pipe , adjustable

 

 

 

 

 

 

 

 

904

4DT-24

SV4L24

24” pipe length

943

4DT-AF6

 

Flashing, 0/12 to 6/12 roof pitch

 

 

 

 

 

 

 

 

903

4DT-36

SV4L36

36” pipe length

943S

4DT-AF12

 

Flashing, 7/12 to 12/12 roof pitch

 

 

 

 

 

 

 

 

902

4DT-48

SV4L48

48” pipe length

 

 

SV4FA

Flashing, 1/12 to 7/12 roof pitch

 

 

 

 

 

 

 

 

945

4DT-EL45

SV4EBR45

45° elbow, black

 

 

SV4FB

Flashing, 8/12 to 12/12 roof pitch

 

 

 

 

 

 

 

 

990

4DT-EL90

SV4EBR90

90° elbow, black

943F

 

SV4F

Flat flashing

 

 

 

 

 

 

 

 

950

4DT-VS

SV4VS

Vinyl siding standoff/sheild

980

4DT-VC

SV4CGV

Vertical termination

 

 

 

 

 

 

 

 

942

4DT-WT

SV4RSN

Wall thimble

991

4DT-HVC

 

High wind vertical termination

 

 

 

 

 

 

 

 

941

4DT-CSS

SV4CSB

Cathedral Support Box

984

4DT-HC

SV4CHC

Horizontal square termination

 

 

 

 

 

 

 

 

981

4DT-ST36

SV4STC36

36” Snorkel Termination

985

4DT-HHC

 

High wind horizontal termination

 

 

 

 

 

 

 

 

953

4DT-SC

SV4FC

Storm collar

978

4DT-VKC

SV0FAK

Vertical termination kit

 

 

 

 

 

 

 

 

963

4DT-FS

SV4BF

Fire stop

970

4DT-HKA

SV0SHK

Horizontal termination kit

 

 

 

 

 

 

 

SD: Basic Kit, SEL: Kit A, SC: Standard Kit

988

4DT-WS/B

SV4BM

Wall strap/support/band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

971

4DT-HKB

SV0SHK2

Horizontal termination kit

 

 

 

 

 

 

 

SD: Kit A, SEL: Kit B, SC: Kit

 

 

 

 

 

 

 

 

This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting. When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When planning an installation, it will be necessary to select the proper length of vent pipe for the particular requirements.

A MINIMUM VERTICAL LENGTH OF 24” (61 cm) TO THE FIRST 90° ELBOW IS REQUIRED. WITH THIS MINIMUM VERTICAL RISE, HORIZONTAL RUNS OF FROM 1 FT (30.5 cm) to 3 FT (91.5 cm) ARE PERMITTED TO REACH THE OUTSIDE VENT TERMINATION.

BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED. FOLLOW THE VENT LENGTH DIAGRAM PRECISELY.

VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING.

If extra elbows are being used, overall allowable length will be reduced by 3 ft (91.5 cm) per additional elbow.

VENT CONFIGURATIONS AND RESTRICTOR SETTINGS:

Figures 12 shows the range of venting options, it shows possible vent configurations if the unit is top vented, for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a longer one.

13

Page 13
Image 13
Enviro C-10794 owner manual Initial Installation, Qualified Installers Only