INSTALLATION (continued)
DANGER: ELECTRICAL SHOCK HAZARD
ELECTRICAL CONNECTIONS MUST BE MADE BY A
LICENSED ELECTRICIAN Electrical shock will cause death or serious injury.
272 304621 Operation Manual for
Refer to the nameplate on the front of the appliance.
•Verify the ELECTRICAL SERVICE POWER.
•Voltage and phase must match the nameplate specifications, and available electrical service amperage must meet or exceed the specifications listed on page 1.
•Wiring must be no less than 4 AWG solid copper wire, rated for at least 90ºC.
NOTE: Wire gauge, insulation type and temperature rating , as well as type, size and construction of conduit, must meet or exceed applicable specifications of local codes and of the National Electrical Code.
1.Electrical connection terminal block and ground lug are accessible by removing the right side panel.
2.This appliance must be connected to a suitable building ground.
The equipment ground connection is marked " | ". |
3.The appliance is shipped from the factory wired for
IMPORTANT: This appliance is not approved for 1Ø operation. Conversion of this appliance to
4.Reinstall right side panel at completion of electrical
CAUTION:
RISK OF
DAMAGE
DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.
CAUTION:
ELECTRICAL SHOCK HAZARD
The ground lug of this appliance must be connected to a suitable building ground.
IMPORTANT:
Contact a licensed electrician to install and connect electrical power to the appliance.
IMPORTANT: Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.
IMPORTANT:
The appliance is shipped from the factory wired for
7