INSTALLATION (continued)
MANUAL PULL STATION LOCATION
FIRE SUPPRESSION AGENT DISPENSING NOZZLES (3 PLACES)
ALL MODELS SHIP
WITH 2 FACTORY- INSTALLED FUSIBLE LINKS
REMOVE REAR PANEL FOR ACCESS TO FIRE SUPPRESSION SYSTEM CONTROLS

INSTALLATION (continued)

DANGER

FIRE

HAZARD

THE FIRE SUPPRESSION SYSTEM MUST BE CHARGED AND CERTIFIED BY AN AUTHORIZED ANSUL® DISTRIBUTOR. NEVER ATTEMPT TO MODIFY OR BYPASS THE FIRE SUPPRESSION SYSTEM.

AN UNCONTROLLED FIRE CAN CAUSE SERIOUS INJURY, DEATH AND/OR PROPERTY LOSS.

FIRE SUPPRESSION SYSTEM INSTALLATION

1.Any REMOTE MANUAL PULL STATION must be installed by an authorized ANSUL® distributor in accordance with the

AUTHORITY HAVING JURISDICTION.

NOTE: If a REMOTE MANUAL PULL STATION is installed, moving the unit for servicing will cause the Ansul® system to discharge. In this case, the unit must only be installed with four fixed legs

(i.e. remove rear casters and replace with legs). Additional legs may be ordered through an Authorized Wells Service Agency. See page 25.

2.The FIRE SUPPRESSION SYSTEM is comprised of a pressurized cartridge &

container of liquid fire

suppressant, with associated plumbing and controls. It utilizes factory installed FUSIBLE LINKS for automatic actuation, and a factory installed

MANUAL PULL STATION for manual actuation. Two NOZZLES are used to disperse the liquid fire suppression media.

IMPORTANT: The FIRE SUPPRESSION SYSTEM must be SET-UP and CHARGED by an authorized Ansul® distributor before the ventilator blower will operate.

NOTE: If the fire suppression system is discharged, a buzzer will sound continu- ously and the cooking appli- ance will remain inoperable until the fire suppression sys-

3.When the fire suppression system activates, the fire suppression media is discharged, both the cooking appliance and the ventilator are de-energized, and a buzzer will sound continuously.

The fire suppression media will form an emulsion designed to both smother and cool the fire.

REAR CASTERSDANGER

REPLACED WITH

LEGS WHEN A

REMOTE MANUAL

PULL STATION

IS INSTALLED

Fig. 6 Fire Suppression System

504 p/n 303903 opM WV

tem is serviced. Recharging and resetting must be per- formed by an authorized Ansul® distributor ONLY.

Charging of the Ansul Fire Suppression system must be in accordance with Ansul® Design, Installation, Recharge and Maintenance Manual. (Ansul® #418087-05)

Call your Authorized Ansul® Distributor immediately for service.

NOTE: See page 22 for the Material Safety Data Sheet for the fire suppression agent.

4.The MANUAL PULL STATION and any similar REMOTE MANUAL PULL STATION will activate the fire suppression system when the ring on the pull station is pulled horizontally.

-4H Ventless Hotplate Cooktop

10

Page 12
Image 12
Wells WV-4HFRWT, WV-4HSRWT INSTALLATION continued, Danger, Fire Suppression System Installation, Fire Hazard