Wells WVOC-G136 operation manual Temperature Calibration, Servicing Instructions, Hot Surface

Models: WVOC-G136

1 34
Download 34 pages 55.86 Kb
Page 25
Image 25
SERVICING INSTRUCTIONS

SERVICING INSTRUCTIONS

509 305936 OpM WVOC-G136

TEMPERATURE CALIBRATION

PRECAUTIONS: The technician is exposed to hot surfaces during this procedure. Wear appropriate protective clothing.

FREQUENCY: Monthly, at a Minimum; or, As Needed

TOOLS: Digital Pyrometer with Oven Probe, Protective Gloves

THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY

1.With the oven empty, clamp the thermocouple sensor in the center of the middle rack:

a.Pass the thermocouple sensor wires through the corner of the door gasket and close the door.

b.Plug the sensor into the Pyrometer.

2.Turn the OVEN POWER (V.01) switch to ON. Turn the FAN switch (V.02) to HI.

a.Rotate the TIME control (V.06) until the time digits (V.05B) on the display read "60:00".

b.Rotate the TEMP control (V.07) until the temp digits (V.05A) display 375º.

c.Press the START TIMER key (V.08).

3.Allow the oven to heat for 45 minutes. If, after 45 minutes, the temperature display reads between 370º and 380º, the calibration is satisfactory. Otherwise:

a.Rotate the TIME controller until the time digits (V.05B) on the display read "00:00".

b.Rotate the TEMP control until the temp digits (V.05A) display between 400º and 500º.

c.Press and hold the START TIMER (V.08) key for five seconds.

d.Turn either the TIME or TEMP control until the desired offset is displayed.

e.Press the ACTUAL TEMP (V.09) key to exit. Procedure is complete.

CAUTION:

HOT SURFACE

Exposed surfaces can be hot to the touch and may cause burns.

23

Page 25
Image 25
Wells WVOC-G136 operation manual Temperature Calibration, Servicing Instructions, Hot Surface