4. SYMPTOM: THE HEART RATE MONITOR DOES NOT FUNCTION PROPERLY

a. See

How to Use the CardioTrack Heart Rate Monitor

on pages 8 and 9, and

Pulse Display

on page 13.

5. SYMPTOM: THE WALKING BELT IS OFF-CENTER WHEN WALKED ON

a.

If the walking belt has shifted to the left

, first remove the key

 

and

UNPLUG THE POWER CORD

. Using the included allen

 

wrench, turn the left rear roller adjustment bolt clockwise, and

 

the right bolt counterclockwise, 1/4 of a turn each. Be careful not

 

to overtighten the walking belt. Plug in the power cord, insert the

 

key and run the treadmill for a few minutes. Repeat until the

 

walking belt is centered.

 

b.

If the walking belt has shifted to the right

, first remove the

 

key and

UNPLUG THE POWER CORD

. Using the allen wrench,

 

turn the left rear roller adjustment bolt counterclockwise, and the

 

right bolt clockwise, 1/4 of a turn each. Be careful not to over-

 

tighten the walking belt. Plug in the power cord, insert the key

 

and run the treadmill for a few minutes. Repeat until the walking

 

belt is centered.

 

c.

If the walking belt slips when walked on

, first remove the key

 

and

UNPLUG THE POWER CORD

. Using the allen wrench, turn

 

both rear roller adjustment bolts clockwise, 1/4 of a turn. When

 

the walking belt is correctly tightened, you should be able to lift

 

the edges

of the walking belt 3 to 4 inches off the walking plat-

form. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few min- utes. Repeat until the walking belt is properly tightened.

a

b

c

6.SYMPTOM: THE WALKING BELT SLOWS WHEN WALKED ON

a. Use only a UL-listed surge protector, rated at 15 amps, with a 14-gauge cord of five feet or less in length.

b. If the walking belt is overtightened, treadmill performance may

 

decrease and the walking belt may be permanently damaged.

 

Remove the key and

UNPLUG THE POWER CORD

. Using the

allen wrench, turn both rear roller adjustment bolts counterclock-

 

wise, 1/4 of a turn. When the walking belt is correctly tightened,

 

you should be able to lift

the edges

of the walking belt 3 to 4

inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is prop- erly tightened.

b

3–4”

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, please contact our Customer Service Department.