MT5634/MT9234 Modem; AT Command Set
Command: &Dn Data Terminal Ready (DTR) Control | ||
Values: | n = 0, 1, 2, or 3 | |
Default: | 2 |
|
Description: | &D0 | Modem ignores true status of DTR signal and responds |
|
| as if it is always on. |
| &D1 | If DTR drops while in online data mode, the modem |
|
| enters command mode, issues an OK, and |
|
| remains connected. |
| &D2 | If DTR drops while in online data mode, the modem |
|
| hangs up. If the signal is not present, the modem will not |
|
| answer or dial. |
| &D3 | If DTR drops, modem hangs up and resets as if ATZ |
|
| command were issued. |
Command: &En XON/XOFF Pacing Control | ||
Values: | n = 12 or 13 | |
Default: | 12 |
|
Description: | &E12 | Disables XON/XOFF pacing. |
| &E13 | Enables XON/XOFF pacing. |
Command: &Fn | Load Factory Settings | |
Values: | n = 0 |
|
Default: | None |
|
Description: | &F0 | Load factory settings as active configuration. |
| Note: See also the Z command. | |
Command: &Gn V.22bis Guard Tone Control | ||
Values: | n = 0, 1, or 2 | |
Default: | 0 |
|
Description: | &G0 | Disable guard tone. |
| &G1 | Set guard tone to 550 Hz. |
| &G2 | Set guard tone to 1800 Hz. |
| Note: The &G command is not used in North America. | |
Command: &Kn Flow Control Selection | ||
Values: | n = 0, 3, or 4 | |
Defaults: | 3 |
|
Description: | &K0 | Disable flow control. |
| &K3 | Enable CTS/RTS hardware flow control. |
| &K4 | Enable XON/XOFF software flow control. |