Whirlpool 819041994, 1188177 manual Troubleshooting, CleaningtheFrontPanel, Annual Maintenance

Models: 819041994 1188177

1 32
Download 32 pages 56.28 Kb
Page 13
Image 13
CleaningtheFrontPanel

CleaningtheFrontPanel

1.Unplug air conditioner or disconnect power.

2.Remove the air filter and clean it separately. See “Cleaning the Air Filter.”

3.Remove the screws from both sides of the air conditioner cabinet.

A

A. Screw

4.Remove the front panel.

5.Clean the front panel using a soft cloth with a mild detergent and warm water. Rinse with clear water and dry.

6.Rinse the control panel and dry thoroughly with a soft, dry cloth.

7.Replace the front panel. Replace screws.

8.Plug in air conditioner or reconnect power.

Annual Maintenance

Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call your local authorized dealer to schedule an annual checkup. The expense of an annual inspection is your responsibility.

TROUBLESHOOTING

You can solve many common air conditioner problems easily, saving you the cost of a service call. Try the suggestions below to see whether you can solve your problem without outside help.

Air conditioner will not operate

The power supply cord is unplugged. Plug into grounded 3 prong outlet. See “Electrical Requirements.”

The power supply cord has tripped (Reset button has popped out). Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation.

A household fuse has blown, or a circuit breaker has tripped. Replace the fuse or reset the circuit breaker. See “Electrical Requirements.”

The Power button has not been pressed. Press POWER.

The local power has failed. Wait for power to be restored.

Air conditioner blows fuses or trips circuit breakers

Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit.

Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See “Electrical Requirements.”

An extension cord is being used. Do not use an extension cord with this or any other appliance.

You are trying to restart the air conditioner too soon after turning off the unit. Wait at least 3 minutes after turning off the unit before trying to restart the air conditioner.

Air conditioner power supply cord trips (Reset button pops out)

Disturbances in your electrical current can trip (Reset button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation.

An electrical overloading, overheating, pinching or aging can trip (Reset button will pop out) the power supply cord. After correcting the problem, press and release RESET (listen for click; Reset button will latch and remain in) to resume operation.

NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

Air conditioner seems to run too much

The current air conditioner replaced an older model. The use of more efficient components may cause the air conditioner to run longer than an older model, but the total energy consumption will be less. Newer air conditioners do not emit the “blast” of cold air you may be accustomed to from older units, but this is not an indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and capacity rating (in BTU/hr.) marked on the air conditioner.

The air conditioner is in a heavily occupied room, or heat- producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat- producing appliances during the hottest part of the day. A higher capacity air conditioner may be required, depending on the size of the room being cooled.