I n Make sure lower edges, back and sides of the cabinet are free of obstructions to permit adequate clearance of air openings for combustton air. See ‘Recessed area and closet installation instructions” for minimum spacing requirements.

J W For ease of installation, operating and servicing (if ever needed), adequate space should be provided around the dryers.

K n A l/&inch, NPT pluaaed tapping, accessible for testgauge connection, must be installed immediately upstream of the gas supply connector to the dryers.

The dryers and their individual shutoff

valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of l/2 psig (3.4 kPa).

The dryers must be isolated from the gas supply piping system by closing their individual manual shutoff valves during any pressure testing of the gas supply piping system at test pressures equal to or less than l/2 psig

(3.4 kPa).

shutott valve -4

l/0”

(3.2mm) pipe plu (for check1 Me7 gas pressure

l/2” (I 2.7 mm), as supply Ine $ lock Iron pipe)

/

ttexlble connector (useA.G.A. desl n- certl1ed connector)

L n If the dryers are installed in a confined area such as a bathroom or closet, they must be exhausted to the outside and provislon made for enough air for combustion and ventilation. (Check governlng codes and ordinances. Also refer to the sectlon of thls Instruction covering ‘Recessed and closet Installations.“)

Electrical reauirements

a

Electrlcal Shock Hazard Electrlcal ground Is required for

dprs.

Do Not ground to a gas pipe.

Do Not change the power supply cord plugs. If plugs will not flt outlets have proper outlets Installed by a quallfled electrlclan.

Do Not have a fuse In the neutral or groundlng clrcult. A tuse In the neutral or groundlng clrcult could result In an electrlcal shock.

Do Not use an extension cord wlth this appliance.

Check wlth a quallfled electrlclan If you are not sure dryers are properly grounded.

Failure to follow these lnstructlons could result In death or serious Injury.

If codes permit and a separate groundlng wire Is used, It Is recommended that a qualltled electrlclan determlne that the groundlng path Is adequate.

OBSERVEALL GOVERNING CODES AND ORDINANCES.

A 230-volt, 50-Hz, AC-only, 15- or

20-ampere fused electrical supply is required. Time-delay fuse or circuit

breaker is recommended. It is

recommended that a separate circuit for the dryers be provided.

Kgrdmended grounding

For your personal safety, these dryers must be grounded. Each dryer is equipped with a power supply cord having a 3-prong grounding plug. To minimize shock hazard, the cords must be plugged into mating 3-prong

grounding-type wall receptacles,

grounded in accordance with local codes and ordinances, If a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, J-prong wall receptacle installed by a quallfled techniclan.

Schuko .

Page 4

Page 4
Image 4
Whirlpool 3402328 Electrical reauirements, Kgrdmended grounding, Electrlcal Shock Hazard Electrlcal ground Is required for