I
n Make sure lower edges, back
and sides of the cabinet are free of
obstructions to permit adequate
clearance of air openings for
combustton air. See ‘Recessed area
and closet installation instructions” for
minimum spacing requirements.
J
W For ease of installation,
operating and servicing (if ever
needed), adequate space should be
provided around the dryers.
K
n A l/&inch, NPT pluaaed
tapping, accessible for testgauge
connection, must be installed
immediately upstream of the gas
supply connector to the dryers.
The dryers and their individual shutoff
valves must be disconnected from
the gas supply piping system during
any pressure testing of that system at
test pressures in excess of l/2 psig
(3.4 kPa).
The dryers must be isolated from the
gas supply piping system by closing
their individual manual shutoff valves
during any pressure testing of the gas
supply piping system at test pressures
equal to or less than l/2 psig
(3.4 kPa).
shutott
valve -4
l/0”
(3.2 mm) pipe
plu (for check1
Me gas pressure
7 s
l/2” (I 2.7 mm),
as supply Ine
$ lock Iron pipe)
/
ttexlble
connector
(use A.G.A.
desl n-
1
certl ed
connector)

L

n If the dryers are installed in a
confined area such as a bathroom or
closet, they must be exhausted to the
outside and provislon made for
enough air for combustion and
ventilation. (Check governlng codes
and ordinances. Also refer to the
sectlon of thls Instruction covering
‘Recessed and closet Installations.“)

Electrical

reauirements

a
Electrlcal Shock Hazard
Electrlcal ground Is required for
dprs.
Do Not ground to a gas pipe.
Do Not change the power supply
cord plugs. If plugs will not flt outlets
have proper outlets Installed by a
quallfled electrlclan.
Do Not have a fuse In the neutral or
groundlng clrcult. A tuse In the
neutral or groundlng clrcult could
result In an electrlcal shock.
Do
Not use an extension cord wlth
this appliance.
Check wlth a quallfled electrlclan If
you are not sure dryers are properly
grounded.
Failure to follow these lnstructlons
could result In death or serious
Injury.
If codes permit and a separate
groundlng wire Is used, It Is
recommended that a qualltled
electrlclan determlne that the
groundlng path Is adequate.
OBSERVE ALL GOVERNING CODES
AND ORDINANCES.
A 230-volt, 50-Hz, AC-only, 15- or
20-ampere fused electrical supply is
required. Time-delay fuse or circuit
breaker is recommended. It is
recommended that a separate
circuit for the dryers be provided.
Kgrdmended grounding
For your personal safety, these dryers
must be grounded. Each dryer is
equipped with a power supply cord
having a 3-prong grounding plug. To
minimize shock hazard, the cords
must be plugged into mating 3-prong
grounding-type wall receptacles,
grounded in accordance with local
codes and ordinances, If a mating
wall receptacle is not available, it is
the personal responsibility and
obligation of the customer to have a
properly grounded, J-prong wall
receptacle installed by a quallfled
techniclan.
Schuko .
Page 4