Recessed area and

closet installation

instructjrons

This dryer may be installed in a
recessed area or closet.
The installation spacing is the
minimum allowable. Additional
spacing should be considered for
ease of installation, servicing and
compliance with local codes and
ordinances.
If closet door is installed, the minimum
unobstructed air openings in the top
and bottom are required. Door must
have two centered openings as
illustrated. Both openings must
provide a minimum of 72 square
inches of unobstructed airflow as
shown. Louvered doors with
equivalent air openings are
acceptable.
Companion appliance spacing
should be considered.
For closet installation, to prevent large
amounts of lint and moisture from
accumulating, to maintain drying
efficiency, and to prevent exposure to
possible health hazards, dryers must
be exhausted outdoors.
Recessed non-exhausted installation
must use only the rear exhaust
position, and Exhaust Deflector Kit,
Part No. 3391278 (electric dryer only),
is required.
Shelf or cabinet is not permitted
above dryer when non-exhausted.
No other fuel-burning appliance may
be installed in the same closet.
Detailed space requirements for
recessed area and closet installations
can be found on the label on the
back panel of the dryer.
Recessed
front view
Side view
Front view 4
Jā€

Product dimensions

Back view
t
35"
.r
28ā€ -
f
b .
1" ICI"+/
Side view
i 6ā€
T

-.f

3.318"
7
*
l
Additional clearances for wall, door
and floor moldings may be required or
if external exhaust elbow is used.
l
* Opening is minimum for closet door.
louvered door with equivalent air
opening is acceptable.