Electrical Shock Hazard Turn power supply off before connecting wires. Use 10 gauge solid copper wire. Electrically ground dryer. Failure to follow these instructions can result in death, fire, or electrical shock.

1

. Turn power supply off.

2

. Strip 3-l /2 inches of outer
covering from end of cable. If using
three-wire cable with ground wire,
cut the bare wire even with outer
covering. Strip 1 inch of insulation
from the end of each insulated wire
(see Figure 17).
Bare wire cut short. Mire is not
used. Dryer is grounded
through dire:t wire cable.

314”

U.L.-listed
wire stripped
of insulation
@omex) I
Direct wire preparation
Figure 17
Shape the end of
each wire into a
u
‘U” shaped hook
~~~~ped (see Figure 18).
Figure
18

3~

. Remove holddown screw and
terminal block cover. -
Figure 19 u

4

. Attach 314” UL- rear
listed strain relief
(U.L. marking on
strain relief) to the
hole below terminal
box opening (see
Figure 20). Tighten
strain relief firmly to
cabinet so it is in a
horizontal position. strain relief
Place direct wire (outside dryer)
cable through strain
Figure 20
relief.

5

. Loosen or remove terminal
block screws. Connect the neutral
wire (white or center) of direct wire
cable under the center screw of
the terminal block. Place the hook-
shaped end of the wire over the
terminal block screw with open side
of the hook facing to the right.
Squeeze hook end of wire together
to form a loop.
Connect the other two wires under
the outer terminal block screws.
Attach wires using the same
method as the neutral wire (see
Figure 21).
Tighten all terminal block screws
firmly.
Center wire MUST be connected to
center screw.
green with external ground
yellow connector
stripes
(attached
at factory) /-
center
screw
(neutral)
red
strain
‘relief
center lea
must be
connected
to center
screw strain
relief
screws screws
-..--.
wire
cable
Figure 21

6

. Tighten strain relief screws.

7

. Insert tab of terminal block
cover into slot of the dryer rear
panel (See Figure 19). Secure
cover with hold-down screw.
Power Supply Cord
or Direct Wire
Where local codes DO NOT
permit connecting the frame-
ground conductor to the
neutral (white) wire:
1
a.
Turn power supply off.
2a. Complete Power Supply Cord
Steps 2-3, Page 7 or Direct Wire Steps
2-4, Pages 7-8. neutral ground
external ground
connector
\
wire -
(green/yello~-
w
striped . ...__\
3;. /
WlW,
must be
-connected
center screw
(neutral) to center
screw
Figure 22
&I. Remove the neutral ground wire
(green/yellow striped wire) from
external ground connector screw.
Remove center terminal block screw
and fasten neutral ground wire to
screw (see Figure 22).
&I. Complete Power Supply Cord
Steps 4-6, Page 7, or Direct Wire Steps
5-7, Page 8.
5a. After reattaching the terminal
block cover, connect separate
copper ground wire from external
ground connector to grounded
metal cold water pipe. Contact a
qualified electrician to assure that
ground path is adequate (see Figure
23).
terminal I
block cover
separate copper ground
wire connected and
grounded to a grounded,
metal, cold water pipe
Figure 23
Page 9