Electrically ground blower.

CWARNING

NOTE: Connect the green (or green/yellow) ground wire from the wiring conduit to the green (or bare) ground wire from the home power supply using UL listed wire connectors (see the “Make Electrical Power Supply Connection to Hood Liner” section).

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

8. Connect the green (or yellow/green) ground wire to the

green/yellow ground wire (H) in the terminal box using UL

listed wire connectors.

B

A

C

D

Make Electrical Power Supply Connectionto Hood Liner E

F

G

H

I

9.

Reinstall the in-line blower terminal box cover and screw.

10.

Reinstall the front cover of the in-line blower housing and

 

secure it with 10 mounting screws.

Electrical Connection Inside Hood Liner Between In-line Blower System and Hood Liner

1.With the hood liner mounted (see the “Install Hood Liner” section), locate the wiring cable connector inside the hood liner.

2.Connect the 6-wire connector assembly supplied with the in-line blower motor system to the mating cable connector from the hood liner.

A. UL listed or CSA approved

F. Blue wires

¹⁄₂" (1.3 cm) wiring conduit

G. Gray wires

B. UL listed wire connectors

H. Green (or green/yellow)

C. Black wires

wire

D. White wires

I. 6-wire connector assembly

E. Red wires

 

7.Go to the “Make Electrical Power Supply Connection to Hood Liner” section.

Make Electrical Power Supply Connection

to Hood Liner

3.Locate the terminal box inside the hood liner and install a ¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see “Complete Preparation” in the “Prepare Location” section).

4.Run the wire ends from the 6-wire connector assembly through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire length to make the wiring connections. Tighten the strain relief screws.

5.Connect the wires from the 6-wire connector assembly to the wires from the wiring conduit inside the hood liner terminal box.

6.Connect the same color wires to each other (black to black, white to white, etc.) using UL listed wire connectors.

Manual backgroundWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Locate terminal box inside of the hood liner.

AB

A.Terminal box cover

B.Terminal box

12

Page 12
Image 12
Whirlpool 48 Make Electrical Power Supply Connection, to Hood Liner, Electrical Shock Hazard, Electrically ground blower