Whirlpool ACE082XH0 manual EN Performing Annual Maintenance

Models: ACE082XH0

1 28
Download 28 pages 60.67 Kb
Page 12
Image 12
EN Performing Annual Maintenance

EN Performing Annual Maintenance

Manual backgroundWARNING

Electrical Shock Hazard Disconnect power before doing any maintenance.

Do not drink water collected by the air conditioner.

Failure to follow these instructions can result in death, electrical shock, or sickness.

Manual backgroundWARNING

Excessive Weight Hazard

Use two or more people to move and install air conditioner.

Failure to do so can result in back or other injury.

3.Remove green ground wire (A) from cabinet base. Keep ground screw

to reattach ground wire after cleaning.

NOTE: Do not lift, push, or pull on any expanded polystyrene (foam) from inside the air conditioner.

4. Pull on handle to remove air conditioner from cabinet. Take care when handling areas with sharp metal fins.

5. Wrap fan motor (B),

G

connector plug (C),

 

electrical control box (D),

and compressor terminals

(E) in plastic film and

 

make sure no water or

 

other liquid gets inside

 

any of these parts. It

 

could damage the

F

insulation and cause

E

serious mechanical

D

problems.

 

A

B

C

H

I

Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call your local authorized dealer to schedule an annual checkup. The expense of an annual inspection is your responsibility. OR

If you are familiar with electrical appliances, you can do the cleaning and maintenance yourself. If you choose to do so, follow these steps:

1.Unplug air conditioner or disconnect power.

2.Remove front panel (See “Cleaning the front panel” on page 10).

6.Carefully clean and hose

out base (F), condenser coil (G), evaporator coil (H), and condensate pan (I). Clean at least once a year or more often if the condenser and evaporator coils and pan collect dirt, sand, leaves, insects, or algae.

Also, clean if you detect an odor coming from the air conditioner.

7.Remove plastic film from motor and electrical parts.

Manual backgroundWARNING

Electrical Shock Hazard Connect green ground wire to ground screw.

Failure to do so can result in death or electrical shock.

8.Replace air conditioner into cabinet. Reattach ground wire to cabinet base with ground screw. Replace front panel.

NOTE: Route power supply cord through notch in front panel. Make sure power supply cord does not interfere with front panel screw.

NOTE: Wait 24 hours before starting the air conditioner again. This allows time for all areas to dry out.

9.Plug in air conditioner or reconnect power.

12

Page 12
Image 12
Whirlpool ACE082XH0 manual EN Performing Annual Maintenance