Location Requirements

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Check the location where air conditioner will be installed. Proper installation is your responsibility. Make sure you have everything necessary for correct installation.

The location should provide:

Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.

NOTE: Do not use an extension cord.

Free movement of air to rooms to be cooled.

A large enough opening for the air conditioner.

Adequate wall support for weight of air conditioner. Air conditioner weighs between 80 and 110 lb (36.3 to 49.9 kg).

NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

A

A. Cabinet louvers

Window installation (on some models)

Window opening measurements:

Width: 28" (71.1 cm) minimum to 40" (101.6 cm) maximum.

Height: 16¹⁄₄" (41.3 cm) minimum.

A

B

A. 28" (71.1 cm) minimum to 40" (101.6 cm) maximum

B. 16¹⁄₄" (41.3 cm) minimum

Through-the-wall installation

The wall opening measurements should be:

Height: 16" (40.6 cm) plus twice the thickness of wood used to build frame.

Width: 22⁵⁄₈" (57.5 cm) plus twice the thickness of wood used to build frame.

C

A

B

C

A. 16" (40.6 cm) + 2 x C

B. 22⁵⁄₈" (57.5 cm) + 2 x C

Electrical Requirements

Window installation (on some models)WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located behind the front panel on the front flange above the coil area.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply cord

 

plug outlet

Wiring requirements

115 volt (103.5 min. -

126.5 max.)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only.