Air conditioner runs
for a short time only,
but room is not cool
Set temperature is close to
room temperature. Lower set temperature. See Using the Controls.
Air conditioner runs,
but does not cool The filter is dirty or
obstructed by debris. Clean the filter.
Air outlet is blocked. Clear air outlet.
Set temperature is too high. Lower set temperature.
The air conditioner has lost
charge (leak in system), or
operated in temperatures
below 64ºF (18ºC).
If the control buzzer beeps 3 times repeatedly, contact service technician.
Air conditioner cycles on and off too much
The air conditioner is set to
ComfortMode control. Use ComfortMode control only when you are asleep or away from home,
since the fan does not circulate the room air continuously.
The air conditioner is not
properly sized for your
room.
Check the cooling capabilities of your portable air conditioner. Portable air
conditioners are not designed to cool multiple rooms.
The filter is dirty or
obstructed by debris. Clean the filter.
There is excessive heat or
moisture (open container
cooking, showers, etc.) in
the room.
Use a fan to exhaust heat or moisture from the room. Try not to use heat-
producing appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner i n a location where the louvers are free from curtains,
blinds, furniture, etc.
The outside temperature is
below 64°F (18°C). Do not try to operate your air conditioner in the cooling mode when the outside
temperature is below 64°F (18°C).
The temperature of the
room you are trying to cool
is extremely hot.
Allow extra time for the air conditioner to cool off a very hot room.
Windows or doors to the
outside are open. Close all windows and doors.
Temperature on
display does not
match room
temperature
When the compressor and
fan motor turn off during
Power Saver mode, or after
you turn off the unit, a lower
temperature reading than
the actual room
temperature may be
displayed for a short period
of time.
This lower temperature reading is caused by the temperature sensor being
located close to the cold evaporator coil. The actual room temperature will
display within a few minutes.
Water dr ips from cabinet into your house
The drain plug is not
installed properly. Install drain plug properly.
Water Full indicator remains on, and the air conditioner turns off
This is normal. See Portable Air Conditioner Care for instructions on how
to drain the air conditioner.