Whirlpool BFG1J5040T3NOV 5K, 6510374 Vent Pipe System, Drafthood Installation, Vent Pipe Size

Models: W10100870 89263 SG1J4040T3NOV 5K BFG1J5040T3NOV 5K 6510374

1 28
Download 28 pages 6.56 Kb
Page 10
Image 10

Vent Pipe System

This water heater uses a non-direct, single-pipe vent system to remove exhaust gases created by the burning of fossil fuels. Air for combustion is taken from the immediate water heater location or is ducted in from the outside (see “Combustion Air Supply and Ventilation”).

This water heater must be properly vented for the removal of exhaust gases to the outside atmosphere. Correct installation of the vent pipe system is mandatory for the proper and efficient operation of this water heater and is an important factor in the life of the unit.

The vent pipe must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition. The vent pipe installation must not be obstructed so as to prevent the removal of exhaust gases to the outside atmosphere.

IMPORTANT: The use of vent dampers is not recommended by the manufacturer of this water heater. Although some vent dampers are certified by CSA International, this certification applies to the vent damper device only and does not mean they are certified for use on this water heater.

U.L. recognized fuel gas and carbon monoxide (CO) detectors are recommended in all applications and should be installed using the manufacturer’s instructions and local codes, rules, or regulations.

IMPORTANT: If you lack the necessary skills required to properly install this venting system, you should not proceed, but get help from a qualified person.

Drafthood Installation

Align the legs of the drafthood with the slots provided. Insert the legs and secure the drafthood to the water heater’s top with the four screws provided as shown in Figure 9. Do not alter the drafthood in any way. If you are replacing an existing water heater, be sure to use the new drafthood supplied with the water heater.

Figure 9

Drafthood Installation

Sheet Metal Screws (four provided)

 

Legs

 

 

 

 

 

 

Drafthood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Legs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slots

 

 

 

 

 

 

 

 

 

Slots

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jacket top

 

 

 

 

 

 

 

 

Install the drafthood with

 

 

 

the four screws provided.

Vent Pipe Size

It is important that you follow the guidelines in these instructions for sizing a vent pipe system. If a transition to a larger vent size is required, the vent transition connection must be made at the drafthood outlet.

Vent Connectors

1.Type B, Double Wall, U.L. Listed Vent Pipe.

2.Single Wall Vent Pipe.

Maintain the manufacturer’s specified minimum clearance from combustible materials when using type B double wall vent pipe.

Vent connectors made of type B, double wall vent pipe material may pass through walls or partitions constructed of combustible material if the minimum listed clearance is maintained.

Maintain a six inch minimum clearance from all combustible materials when using singlewall vent pipe.

IMPORTANT: Single wall vent pipe cannot be used for water heaters located in attics and may not pass through attic spaces, crawl spaces or any confined or inaccessible location. A single wall metal vent connector cannot pass through any interior wall.

When installing a vent connector, please note the following:

Install the vent connector avoiding unnecessary bends, which create resistance to the flow of vent gases.

Install without dips or sags with an upward slope of at least 1/4-inch per foot.

Joints must be fastened by sheet metal screws or other approved means. It must be supported to maintain clearances and prevent separation of joints and damage.

The length of the vent connector cannot exceed 75% of the vertical vent height.

The vent connector must be accessible for cleaning, inspection, and replacement.

Vent connectors cannot pass through any ceiling, floor, firewall, or fire partition.

IMPORTANT: Existing vent systems must be inspected for obstructions, corrosion, and proper installation.

10

Page 10
Image 10
Whirlpool BFG1J5040T3NOV 5K, 6510374, W10100870 Vent Pipe System, Drafthood Installation, Vent Pipe Size, Vent Connectors

W10100870, 89263, SG1J4040T3NOV 5K, BFG1J5040T3NOV 5K, 6510374 specifications

Whirlpool is a leading name in the home appliances industry, known for its innovative technology and user-friendly designs. Among its extensive product range, various models stand out for their unique features and capabilities. Such models include the Whirlpool 6510374, BFG1J5040T3NOV 5K, SG1J4040T3NOV 5K, 89263, and W10100870, each designed to enhance functionality and convenience in kitchen environments and more.

The Whirlpool 6510374 is a versatile appliance often used for its high efficiency and reliable performance. It includes features like adjustable shelves, which provide flexibility in arranging your items to maximize storage space. The smart cooling technology ensures uniform cooling throughout the unit, preserving the freshness of perishables for extended periods.

Next, the BFG1J5040T3NOV 5K offers advanced features tailored for energy efficiency. Its high efficiency compressor not only provides optimal cooling but also helps consumers save on energy bills. Furthermore, it includes a user-friendly digital display that allows for precise temperature control and easy monitoring, catering to the needs of modern families.

The SG1J4040T3NOV 5K model enhances user convenience with features such as a frost-free design, which eliminates the need for manual defrosting, saving both time and effort. This feature, combined with its spacious interior, makes it highly desirable for storing large quantities of food.

Model 89263 focuses on ease of use and maintenance. With its intuitive interface and durable construction, this model stands out in terms of reliability. Its robust design ensures longevity while maintaining performance, making it a dependable choice for families.

Lastly, the W10100870 offers unique characteristics centered around connectivity and technology. Equipped with smart features, it allows users to connect their devices and control settings remotely. This model exemplifies the shift towards smart home technology, creating a seamless integration of appliances into daily life.

In conclusion, the Whirlpool 6510374, BFG1J5040T3NOV 5K, SG1J4040T3NOV 5K, 89263, and W10100870 each present an array of features that enhance functionality, efficiency, and user experience. Whirlpool continues to push boundaries in appliance design, ensuring that each model is a safe, reliable, and smart choice for consumers worldwide. These models reflect the brand’s commitment to quality, innovation, and customer satisfaction, making them an essential part of any modern kitchen.