Receptacle wiring

Use 14 gauge (minimum) wire for receptacle wiring. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe the National Electrical Code and all local governing codes and ordinances.

Electrical requirements

A 115 Volt (103.5 min., 126.5 max.), 60 Hz. AC only, 15 ampere fused electrical supply is required. Use a time-delay fuse or circuit breaker. It is required that a separate circuit. serving only this appliance, be provided.

Electrical connection

Electrical ground is required on this appliance.

Alambrado del tomacorriente

El alambrado del tomacorriente tiene que ser de calibre 14 coma minimo. Usar alambre de cobre solamente. Es la responsabilidad del consumidor proveer alambrado del tomacorriente adecuado y apropiado, instalado por un electricista calificado. Cumplir el Codigo National de Electricidad y todos 10s codigos y reglamentos locales vigentes.

Requerimientos elhctricos

Se requiere un siministro electrico con fusible de 115 voltios (103.5 min., 126.5 max.), 60 Hz, CA de 15 amperios solamete. Usar un fusible de action retardada o disyuntor de action retardada. Se requiere que se provea un circuit0 separado para ser usado por este artefacto solamente.

Conexih ektrica

Este ar-tefacto debe ser puesto a tierra.

10

Page 10
Image 10
Whirlpool BHAC0600BS0 manual Receptacle wiring, Electrical requirements, Electrical connection, Alambrado del tomacorriente