Models: KTLA22EMSS04 KTRA19EMBT00 KTRA19EMBT01 KTRA22EMBL03 KTRA22EMBT02 KTRC22EMBT02 KTRA22EMBL02 KTRA19EMWH01 KTRA19EMBL00 KTRA22EMSS01 KTRA22EMSS02 KTRA19EMWH00 KTRA22EMBT03 KTRA19EMSS00 KTRA19EMSS01 KTRA19EMBL01 KTRA22EMBL01 KTRA22EMBT01 KTRC22EMBL02 KTRS22EMBT01 KTRC22EMSS02 KTRS22EMWH00 KTRS22EMBL00 KTRS22EMBT00 KTRS22EMWH01 KTRC22EMWH02 KTRS22EMSS00 KTRS22EMSS01 KTRS22EMBL01 KTRP22EMBT03 KTRP22EMBT02 KTRP22EMBL02 KTRP22EMSS02 KTRP22EMSS01 KTRP22EMSS00 KTRP22EMWH00 KTRP22EMBL01 KTRP22EMBT04 KTRP22EMBT01 KTRP22EMWH04 KTRP22EMWH01 KTRP22EMWH02 KTRP22EMWH03 KTLA19EMSS01 KTRA22EMWH01 KTLA19EMSS00 KTRA22EMWH03 KTLA22EMSS02 KTRA22EMSS03 KTRA22EMSS04 KTRA22EMWH02 KTLA22EMSS01 KTLA22EMSS03 ED5NTGXMQ00

1 56
Download 56 pages 61.18 Kb
Page 25
Image 25
PRODUCT DATA SHEETS

PRODUCT DATA SHEETS

Base Grille Water Filtration System

Model WF-NL240/NL240 Capacity 240 Gallons (908 Liters)

Model WF-L400/L400 Capacity 400 Gallons (1514 Liters)

Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine, Taste and Odor, Particulate Class II*; and against ANSI/NSF Standard 53 for the reduction of Lead.

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

NSF Test

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50%

2.0 mg/L

2.0 mg/L ± 10%

0.03 mg/L

0.025 mg/L

98.5%

99.0%

504232-01

Particulate Class II*

85%

833,333/mL

At least 10,000

100,000/mL**

40,667/mL

88.0%

95.1%

507163-02

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge Maximum

Average

Minimum %

Average %

NSF Test

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

Number

 

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.01mg/L

0.16 mg/L***

0.15 mg/L ± 10%

0.001 mg/L

0.001 mg/L

99.35%

99.35%

507610-01

Lead: @ pH 8.5

0.01mg/L

0.15 mg/L***

0.15 mg/L ± 10%

0.001 mg/L

0.001 mg/L

99.31%

99.31%

507611-01

 

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model WF-NL240Change cartridge at least every 6-9 months. Use replacement cartridge NL240, part# 4396508. 2003 suggested retail price of $32.99 U.S.A./$49.95 Canada. Prices are subject to change without notice.

Model WF-L400The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge L400,

Part #4396508. 2003 suggested retail price of $32.99 U.S.A./ $49.95 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Refer to the front cover or “Assistance or Service” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8° C)

Service Flow Rate

0.5 gpm (1.9 L/min.) @ 60 psi.

 

 

*Class II particle size: >1 to <5