Installation Requirements

Installation Requirements

LOCATION REQUIREMENTS

Consider all of the following when selecting an installa- tion location for the water softener.

=Do not locate the water softener where freezing temperatures occur. Do not attempt to treat water over 120ºF. Freezing temperatures or hot water damage voids the warranty.

=To condition all water in the home, install the water softener close to the water supply inlet, and upstream of all other plumbing connections, except outside water pipes. Outside faucets should remain on hard water to avoid wasting conditioned water and salt.

=A nearby drain is needed to carry away regenera- tion discharge (drain) water. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). See "Air Gap Requirements" and "Valve Drain Requirements" sections.

=The water softener works on 24 volt, 60 Hz electri- cal power only, supplied by a direct plug-in trans- former (included). Provide an electrical outlet within 10 feet, in accordance with NEC and local codes.

=Always install the water softener between the water inlet and water heater. Any other installed water conditioning equipment should be installed between the water inlet and water softener (See Figure 4 below).

=Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non- metallic parts.

PLUMBING CODES

All plumbing must be completed in accordance with national, state and local plumbing codes.

In the state of Massachusetts: The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation.

AIR GAP REQUIREMENTS

A drain is needed for regeneration water (See Figure 3). A floor drain, close to the water softener, is preferred. A laundry tub, standpipe, etc. are other drain options. Secure valve drain hose in place. Leave an air gap of 1-1/2” between the end of the hose and the drain. This gap is needed to prevent backflow of sewer water into the water softener. Do not put the end of the drain hose into the drain.

 

 

Drain

Drain

 

Drain

Hose

Hose

1-1/2”

Hose

 

 

 

 

 

air gap

 

 

 

 

1-1/2”

 

 

 

air gap

1-1/2”

 

 

 

air gap

 

FLOOR DRAIN

STANDPIPE

LAUNDRY TUB

FIG. 3

THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT

Untreated Water to Cold Water Outside Faucets to House

LOCATION REQUIREMENTSPLUMBING CODES City Water Supply

Hot Water

Optional

Pressure

OR

to House

Tank

 

Sediment

 

Filter

 

 

Water

Water

Well Water Supply

Heater

Softener

Well

 

 

 

 

Pump

FIG. 4