Button | Normal Functions | cont. | |
|
|
| |
Energy | 1. | The ER feature can be used to save energy and aids in extending the life of the system. | |
Reduc- | 2. | The ER button is located at the top L/H side of the control. The ER feature is activated by | |
tion | 3. | pressing the ER button one time, and the ER logo will appear on the digital display. | |
(ER) | The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up by 4 | ||
| degrees, which will allow the cooling system to run for shorter periods of time, resulting | ||
|
| ||
|
| in a reduction in energy cost. |
|
| 4. | The ER feature allows for Energy Savings at any time - During periods of high ambient | |
|
| temperatures, vacations or business travel. |
|
| 5. | To deactivate the ER feature, press the ER button one time, and the ER logo will turn off. | |
| 6. | The ER feature can be conveniently adjusted to the customer’s specific | needs, by accessing |
|
| the “Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode | |
|
| Instructions. |
|
|
|
| |
Set | 1. | Press the “Set” button once and it will display the Set Point. After approximately 5 sec- | |
Button |
| onds, the display will return to normal operation and display the Bottle Probe tempera- | |
|
| ture. |
|
| 2. | Press and hold the “Set” button for | |
|
| symbol starts blinking. Next press the “UP or Down” arrows to change the Set Point. Next | |
|
| press the “Set” button once and the Set Point numbers and the °F on the display will blink | |
|
| to confirm the new Set Point setting. |
|
| 3. | Press the “Set” and the “Down Arrow” buttons simultaneously, for | |
|
| access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the customer | |
|
| to “Fine Tune” the Control Operating System to their applicable choice. |
|
|
| ||
CPSM | The “Customer Preference Selection Mode” (CPSM) allows the customer to fine tune the con- | ||
Mode | trol operating system to their specific needs. |
| |
| • Press the “Set” and the Down Arrow” buttons simultaneously for | ||
|
| play will show CF, and the F symbol in the top right corner will be blinking. | |
| • Press the “Set” and “Down Arrow Buttons” again but this time hold for | ||
| activate the “Customer Preference Selection Mode” (CPSM). |
| |
| The following CPSM options are available for adjustment: |
| |
| • Fon – Humidity Management Enhancement: This parameter is normally set at 5, which | ||
| should provide adequate relative humidity for the cellar. |
| |
|
| • An increase in this parameter will increase the Humidity Enhancement (%RH), and a | |
|
| decrease in the parameter will decrease Humidity Enhancement (%RH). | |
|
| • Adjustments should be made in increments of 5, with a maximum of 15, and a mini- | |
|
| mum of 0. |
|
|
| • After any adjustment to Humidity Enhancement, you should wait a minimum of three | |
|
| days before making any additional adjustments. This will allow the cellar sufficient time | |
|
| to acclimate to the new setting. |
|
|
|
|
|
Page 16 | SL 072710 |