USING THE WHISPERKOOL SYSTEM
Power Switch
XLT units, built after June 2007, come equipped with a
NOTE; (It will take five minutes before the unit begins to operate once the switch is placed in the “On” position. This is due to the designed safety delay in the PDT thermostat.)
®
POWER
FRONT
OFF
REAR
Switches
Location of control switches
Condensate Evaporator Switch
The Condensate Evaporator is a heating element that automatically evaporates excess condensate that accumulates in the cooling system as a
WRONG: Drainline is under water.
Drain line
Drain Line
All units come with a drain line for additional removal of excessive condensate. This is a back up system to the Condensate Evaporator. It is mandatory to install the drain line attachment. During operation, the cooling unit will strip excess water from the air in order to maintain the proper level of humidity within the cellar. The Condensate Evaporator will heat and dissipate the excess moisture through the rear of the unit. However in extreme humidity, additional condensate will be created. Conversely the high humidity air has less capacity to absorb additional moisture through the exhaust of the unit. Thus the drain line will prevent overflow and leaking by allowing for discharge of the additional condensate. WhisperKOOL carries a condensate pump kit, which allows the excess condensate to be pumped up to 20 ft. away from the unit. See page 29 for details.
Failure to install the drain line voids warranty.
To prevent mold from growing, allow the drainline to hang above the water line.
Page 13 | XLT 020111 |