TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

Before contacting Customer Service regarding a performance issue with your cooling unit (does not cool, leaks, ices up, etc.), please review the following troubleshooting information and complete the Troubleshooting Checklist found on page 24. It is designed to help you identify the issue yourself and provide appropriate advice to remedy the issue or problem.

If you are unable to identify or solve the issue after completing and following these steps, fax a com- pleted Troubleshooting Checklist to WhisperKOOL Customer Service at 1(209) 466-9606. The checklist will provide Customer Service with background information on your cooling unit installation and wine cellar to better assist you in resolving the issue. Be sure to include accurate contact information.

 

 

 

 

 

 

Problem

Likely Cause

Remedy

 

 

 

The unit does not

 

 

 

 

 

Inadequate door seal

See “Door Seal” section on pg. 20

cool the room

Improperly mounted unit

See “Unit Mounting” section on pg. 21

 

 

Unit has inadequate ventilation

See “Airflow” and “Ventilation” sections on pg. 19 &

20

 

Foam strips are not attached

See page 11 (in the "Installation" section)

 

 

 

 

 

 

 

 

 

Water leaking

Condensate Evaporator is not

See Water Leaking, Rear in the “Condensation”

from the rear

properly set for local climate

section on pg. 22

 

Drain line is not attached

See “Drain line” section on pg. 13

 

 

 

 

 

 

 

 

Unit is icing up

Poor Air Flow

See “Thermostat” section on pg. 21

 

Unit is low on refrigerant

See “Icing Up” section on pg. 22

 

 

Probe not in bottle

See “Liquid Measuring Thermosat” section on pg. 14

 

 

 

 

 

 

 

Unit isn’t running

Problem with local electrical

See “Power Requirements” section on pg. 22

or makes intermittent

circuit

 

 

 

 

 

clicking noises

 

 

 

 

 

 

 

 

 

 

 

 

 

Try this first!

Clean off any accumulated dust, lint, or other debris from the front and rear intake grills. This will restrict the airflow and may affect the unit’s ability to function properly. Periodically cleaning the unit’s vents will help assure maximum cooling efficiency.

Airflow

Proper airflow is critical to the performance of the WhisperKOOL unit. Any obstruction to the intake and exhaust ports on either side of the unit will compromise the unit’s ability to cool. Make sure the WhisperKOOL unit fan vents are clear. Check the front and rear intake vents for any possible obstruction. There should be a minimum clearance of three feet directly in front of the intake and exhaust vents.