FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLYBEFOREINSTALLINGOROPERATINGTHIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

1F85RF-275 Thermostat and Wireless Remote Sensor Kit

Automatic Heat/Cool Changeover Thermostat for Single Stage/ Multi-Stage/Heat Pump Systems with Wireless Remote Sensor

Installation and Operating Instructions for Model:

 

 

 

Model

Programming Choices

1F85RF-270

Non-Programmable

5/1/1 Day

F145RF-1328

Wireless Remote Sensor

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

Description

 

 

Heat Pump (No Auxiliary or Emergency Heat)

Yes

 

 

 

Heat Pump (with Auxiliary or Emergency Heat)

Yes

 

 

 

Standard Heat & Cooling Systems

Yes

 

 

Multi-Stage Systems requiring more than

Yes

 

One Call for Heat or Cool

 

 

 

 

 

Standard Heat Only Systems

Yes

 

 

Millivolt Heat Only Systems – Floor or Wall Furnaces

No

 

 

 

 

Standard Central Air Conditioning

Yes

 

 

 

Gas or Oil Heat

Yes

 

 

1F85RF-270

Electric Furnace

 

Yes

 

Hydronic (Hot Water) Zone Heat – 2 Wires

* Yes

 

 

 

Hydronic (Hot Water) Zone Heat – 3 Wires

No

* Common Connection Required

Wireless Remote Sensor

SPECIFICATIONS

Thermostat:

Electrical Ratings

20 to 30 VAC 50/60 Hz

 

0.2 to 0.6 Amps per Load

 

(Y1, E/W1, G)

 

1.5 Amps (Y2, W2, O, B

 

Load per terminal)

 

1.5 Amps Max

 

(All terminals combined)

Setpoint Range

45 to 90°F (7 to 32°C)

Rated Differential (Single Stage) ...

Heat 0.6° or 1.5°F, Cool 1.2°F

Rated Differential (Multi-Stage)

Heat 0.6° or 1.5°F, Cool 1.2°F

Rated Differential (Heat Pump)

Heat & Cool 0.75° or 1.2°F

Operating Ambient

32 to +105°F (0 to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temp. Range

-4 to +150°F (-20 to +65°C)

Thermostat Dimensions

3-3/4"H x 6"W x 1-1/4"D

Remote Sensor:

This device complies with Part 15 of the FCC Rules, Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Maximum Wireless Remote Sensors

1 indoor, 1 outdoor

Operating Range

45 to 90°F (7 to 32°C)

Operating Humidity Range

0 to 90% RH

 

(non-condensing)

Dimensions

2-5/8"H x 4-1/4"W x 7/8"D

* Max. Distance from Thermostat

200 feet

*Distance shown is for a typical application. Distances may vary in some applications because obstacles that block the signal path may affect the strength of the signal.

!CAUTION

To prevent electrical shock and/or equipment dam- age, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

 

 

Index

Page

Installation

2

Wiring Connections

3

Thermostat/Sensor Quick Reference

4

Installer Configuration Menus

6

Operating Your Thermostat and Sensor

9

Programming

13

Troubleshooting

14

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this prod- uct may replace a product which contains mercury.

Mercury and products containing mercury must not be dis- carded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container and send it to:

White-Rodgers

2895 Harrison Street

Batesville, AR 72501

PART NO. 37-6841B

www.white-rodgers.com

Replaces 37-6841A

 

0745