ADJUSTABLE HEATING AND COOLING CYCLE TIMES (ANTICIPATION) — If the heating/cooling system is turning on and off too often (short cycles) or not often enough (long cycles), you may want to adjust the anticipation setting.

!CAUTION

A cooling anticipation setting of less than 10 may cause decreased compres- sor life.

To adjust anticipation, press CLOCKSET and ADVDAY at the same time. The display will show HEAT 8 (this is the factory preprogrammed heating anticipation setting). You may se- lect any anticipation setting from 4 to 40.

If the heat cycles are too short, press TIMEFWD to increase the cycle time. If the heat cycles

are too long, press BACKTIME to decrease the cycle time. To set cooling anticipation, press

CLOCKSET and ADVDAY at the same time again. The display will show COOL 14 (factory prepro- grammed cooling anticipation). Use the TIMEFWD

and

BACKTIME buttons to adjust anticipation. Press

PRGMRUN

to return to your program.

LOW BATTERY INDICATOR — The word BATTERY will flash on the display if the 9 volt alkaline battery is low and should be replaced.