too long, press BACKTIME to decrease the cycle
SET
time. To set cooling anticipation, press CLOCK
and ADVDAY at the same time again. The display will show COOL 14 (factory preprogrammed cooling anticipation). Use the TIMEFWD and BACKTIME
buttons to adjust anticipation. Press PRGMRUN to
return to your program.
•LOW BATTERY INDICATOR — The three "AA" alkaline batteries will maintain thermo- stat programming for approximately one year if power to the thermostat fails. The word BATTERY will flash on the display if the "AA" alkaline batteries are low and should be re- placed. The thermostat will also make a beeping sound every five minutes when bat- teries need replacing. To override the beep- ing, press any button on the keypad. The
beeping will stop for 15 hours, then start again. You may again stop the beeping by pressing any button on the keypad. After turning the beep off three times, the thermostat will quit beeping. However, you should always change the batteries as soon as possible to ensure that programming will not be lost in the event of a power outage. You should also change the batteries at least once a year.
!CAUTION
Fresh batteries must always be installed for millivolt systems. The heating system will not operate if batteries are not installed or if battery power is low.
The word BATTERY will be displayed continu- ously
16