During periods of low humidity (especially during cold weather), you may feel or see a spark discharge when you touch the thermo- stat. This may cause the program to be lost or the thermostat to display incorrectly. To cor- rect this, remove the thermostat from the wall and disconnect the battery. Wait about two minutes, then reconnect the battery. The thermostat will revert to the factory preset program until you reprogram the thermostat. If you don’t want to reprogram the thermostat

immediately, press

SYSTEM

until OFF is dis-

SWITCH

played and replace the thermostat on the wall.

Then press

RUN

to begin the factory preset

PRGM

program. Or you may reprogram the thermo- stat, then replace it on the wall.

To prevent further static discharge problems, touch another object to release static build-up before touching the thermostat. See OPER-

ATING YOUR THERMOSTAT.

8.Why won’t the setpoint temperature go to the temperature I want?

In the AUTO mode, the highest heating setpoint temperature you select must be at least 1°F

lower than the lowest cooling setpoint tem- perature you select (for example, if 70°F is your lowest selected cooling temperature, you

cannot select a heating temperature any higher than 68°F). If such a conflict exists, you must set the lowest cooling temperature higher in order to set the heating temperature higher. To set a lower cooling temperature, you must select a lower heating temperature. See PRO-

GRAMMING YOUR THERMOSTAT.

35