TRIDENT COMPACT 17" 230V/240V | Page 9 of 27 |
VACUUM
MOTOR
1.Unplugthe machlne from outlet.
2.Remove (6) bolts holdingvac motor/ plate assembly to recovery tank.
3.Disconnectvac motor lead from connector and lift out vac motor/ plate assembly.
4.Check motor brushes. When worn to 318" replace
both brushes.
After the machine has been used for any wet
HazardousVoltage. Shock can result. Unplug mahcine before servicing machine. Only qualified personnel should work inside ma- chine.
Wire Terminal | Import8nt: | |||
When replacing | ||||
| ||||
| carbon | vac motor | ||
| brushes | loosen wire | ||
| terminal | BEFORE re- | ||
| moving | screws on | ||
| bracket. |
| ||
|
|
|
| |
|
|
| Wire | |
Importsnt: |
|
| ||
|
|
|
Replace carbon vac motor brushes if worn down to 318"in length. These brushes wear quicker as the length shortens due to increased heat.
Spring inside brush housing will damage motor if brushes are allowed to completely wear away.
Note: Place stopIn groove.
NOTE: Periodically check the length of the carbon brushes. ReDlace carbon brushes which 8re less
MAINTENANCE
BRUSH
Brush Installation:1.Slide brush or pad driver under drive plate.
2.Align one metal lug on the brush or
pad driver with the scrub deck sight hole and a keyhole in the drive plate.
3.Raise the brush or pad driver upward and twist clockwise until locked.
Brush Removal:1.Raise brush or pad driver off floor.
2.Reach under brush or pad driver and rotate so that the metal lug in the drive plate is visible through the scrub deck sight hole.
3.Quickly twist brush or pad driver counterclockwise to release.
SOLUTION STRAINER
1.An inline solution strainer is located under chassis behind left wheel. Remove sediment bowl and screen periodically and rinse clean with hot water. Be careful not to misplacethe gasket.
-
PART NO. 74695 | U |