VACUUM

MOTOR

1.Unplugthe machlne from outlet.

2.Remove (6) bolts holdingvac motor/ plate assembly to recovery tank.

3.Disconnectvac motor lead from connector and lift out vac motor/ plate assembly.

4.Check motor brushes. When worn to 318" replace

both brushes.

After the machine has been used for any wet pick-up, allow the vacuum motor to run 1-2 minutes, to help re- duce moisture build-up in the vacuum motor. Drying out the vacuum motor after each usewill extend the life of your vacuum motor.

HazardousVoltage. Shock can result. Unplug mahcine before servicing machine. Only qualified personnel should work inside ma- chine.

Wire Terminal

Import8nt:

When replacing

 

 

carbon

vac motor

 

brushes

loosen wire

 

terminal

BEFORE re-

 

moving

screws on

 

bracket.

 

 

 

 

 

 

 

 

Wire

Importsnt:

 

 

 

 

 

Replace carbon vac motor brushes if worn down to 318"in length. These brushes wear quicker as the length shortens due to increased heat.

Spring inside brush housing will damage motor if brushes are allowed to completely wear away.

Note: Place stop

In groove.

NOTE: Periodically check the length of the carbon brushes. ReDlace carbon brushes which 8re less

MAINTENANCE

BRUSH

Brush Installation:

1.Slide brush or pad driver under drive plate.

2.Align one metal lug on the brush or

pad driver with the scrub deck sight hole and a keyhole in the drive plate.

3.Raise the brush or pad driver upward and twist clockwise until locked.

Brush Removal:

1.Raise brush or pad driver off floor.

2.Reach under brush or pad driver and rotate so that the metal lug in the drive plate is visible through the scrub deck sight hole.

3.Quickly twist brush or pad driver counterclockwise to release.

SOLUTION STRAINER

1.An inline solution strainer is located under chassis behind left wheel. Remove sediment bowl and screen periodically and rinse clean with hot water. Be careful not to misplacethe gasket.

han 3/8"lo&.

-

PART NO. 74695