Page 8
Image 8
POTENTIAL INJURY:

POTENTIAL INJURY:

Warning:

This product contains moving parts.

To reduce the risk of injury - unplug the machine before servicing.

Maintenance and repairs must be done by qualified personnel ONLY.

CAUTION:

Using non-Windsor parts to repair this machine will void the 6-3-l warranty.

Suggested Service Parts List

 

DESCRIPTION

PART NUMBER

 

Belt

 

11015

 

 

Brush Bearinas

09019

 

 

115V Cord Assemblv (USA/Japan) 23086

 

115V Cord End (USA)

26009

 

 

Dome Assemblv

28033

 

 

Dome Gasket

35060

 

 

Hose Cuff, Blue

27354

 

 

Hose Cuff, White

27079

 

 

Jet Assemblv

 

44055

 

 

Jet

 

44061

 

 

Jet Seal

 

44051

 

 

Jet Bodv w/Seal

44052

 

 

Manifold Assemblv

54095

 

 

Screen/Filter,

Dome

34140

 

 

Screen/Filter.

Solution Tank

73772

 

 

 

 

 

 

 

 

 

 

 

DAILY MAINTENANCE:

These procedures are followed at the end of each work period to extend the life of the machine.

1.) Empty unused cleaning solution by dis- connecting clear hose on back of machine and pouring into floor drain.

2.) Inspect and clean solution filter screen inside tank and vac intake screen inside dome.

3.) Flush the system. Fill solution tank with 1 or 2 gallons (4 - 8 liters) of clean ot water. With machine over floor drain turn on vac/pump switch until solution tank is empty.

4.) Inspect spray pattern of jets. Remove jets and rinse if clogged.

5.) After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a l-1 0 bleach to water solution. Waste water should be disposed of properly.

6.) Remove any lint or debris from brush.

7.) Inspect power cord. Remember, this cord will lay on damp carpet.

Warning: IMMEDIATELY REPLACE WORN OR FRAYED POWER CORDS.

8.) Inspect hoses. Worn or cracked hoses may cause loss of vac pressure.

9.) Place the brush in the storage position. Press back slightly on the main handle, press down on the control knob and turn until the pin drops into the slot; rotate another 90”to lock.

For infrequent use or long periods of storage, flush the system with a neutralizing solution of 1 quart (1 liter) white vinegar mixed with 2 gallons (8 liters) hot water. Flush the system with clean hot water after neutralizing.