POTENTIAL INJURY:
Warning:
This product contains moving parts.
To reduce the risk of injury - unplug the machine before servicing.
Maintenance and repairs must be done by qualified personnel ONLY.
CAUTION:
Using
Suggested Service Parts List
| DESCRIPTION | PART NUMBER | ||
| Belt |
| 11015 |
|
| Brush Bearinas | 09019 |
| |
| 115V Cord Assemblv (USA/Japan) 23086 | |||
| 115V Cord End (USA) | 26009 |
| |
| Dome Assemblv | 28033 |
| |
| Dome Gasket | 35060 |
| |
| Hose Cuff, Blue | 27354 |
| |
| Hose Cuff, White | 27079 |
| |
| Jet Assemblv |
| 44055 |
|
| Jet |
| 44061 |
|
| Jet Seal |
| 44051 |
|
| Jet Bodv w/Seal | 44052 |
| |
| Manifold Assemblv | 54095 |
| |
| Screen/Filter, | Dome | 34140 |
|
| Screen/Filter. | Solution Tank | 73772 |
|
|
|
|
|
|
|
|
|
|
|
DAILY MAINTENANCE:
These procedures are followed at the end of each work period to extend the life of the machine.
1.) Empty unused cleaning solution by dis- connecting clear hose on back of machine and pouring into floor drain.
2.) Inspect and clean solution filter screen inside tank and vac intake screen inside dome.
3.) Flush the system. Fill solution tank with 1 or 2 gallons (4 - 8 liters) of clean ot water. With machine over floor drain turn on vac/pump switch until solution tank is empty.
4.) Inspect spray pattern of jets. Remove jets and rinse if clogged.
5.) After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a
6.) Remove any lint or debris from brush.
7.) Inspect power cord. Remember, this cord will lay on damp carpet.
Warning: IMMEDIATELY REPLACE WORN OR FRAYED POWER CORDS.
8.) Inspect hoses. Worn or cracked hoses may cause loss of vac pressure.
9.) Place the brush in the storage position. Press back slightly on the main handle, press down on the control knob and turn until the pin drops into the slot; rotate another 90”to lock.
For infrequent use or long periods of storage, flush the system with a neutralizing solution of 1 quart (1 liter) white vinegar mixed with 2 gallons (8 liters) hot water. Flush the system with clean hot water after neutralizing.
8 | 98198 | 7/l/97 |
|