Windsor QTFSD, QTFSG 4-14, Maintenance, Battery, When servicing machine, avoid contact with acid

Models: QTFSG QTFSD

1 35
Download 35 pages 20.62 Kb
Page 31
Image 31
BATTERY

BATTERY

The battery provides the power to start the machine. The battery requires regular maintenance to keep them operating at peak efficiency.

To get the greatest life from the battery charge it when their charge level reaches 25%of a full charge. Use a hydrometer to check the charge level.

Do not allow the battery to remain in a discharged condition for any length of time. Never expose a discharged battery to temperatures below freezing. Discharged batteries will freeze causing cracked case. Do not operate the machine if the battery is in poor condition or if they have a charge level below 25%, specific gravity below 1.177.

Keep all metallic objects off the top of the battery, as they may cause a short circuit. Replace worn or damaged cables and terminals.

Check the electrolyte level in each battery cell before and after charging the battery. Never add acid to the battery, use water. Do not allow water level to fall below the battery plates. Portions of plates exposed to air will be destroyed. Do not overfill. Keep plugs firmly in place at all times.

The battery in this machine is rated at 12V, 550cca. It is located under the engine, center of frame. When removing the battery cables, remove the negative (-) cable before removing the positive (+) cable.

When servicing machine, avoid contact with acid.! Charge batteries in a well-ventilated area.

When servicing machine, avoid contact with acid.

BATTERY MAINTENANCE! 4-14

Batteries emit hydrogen gas. Explosion or fire can result. Keep sparks and open flame away. Keep covers open when charging.

Manual background! Manual background

Wear eye protection and protective clothing when working with batteries.

Manual background! Manual background

Charge batteries in a well-ventilated area.

MAINTENANCE

BATTERY MAINTENANCE

1.When cleaning the battery, use a solution of baking soda and water. Do not allow the cleaning fluid to enter the battery cells. Electrolyte will be neutralized.

2.Maintain the proper electrolyte level in each battery cell. If a cell should accidentally overflow, clean immediately.

3.Do not add water until the battery is fully charged.

4.Wipe off the top of the batteries at least once a week.

5.Test battery condition with a hydrometer at least once a week.

6.Ensure that all connections are tight and all corrosion removed.

7.Every 4 to 6 months, remove the batteries from the machine and clean the battery cases and battery compartment.

NOTE: Do not take readings immediately after adding water. If the water and acid are not thoroughly mixed, the reading may not be accurate.

To find the correct specific gravity reading when the temperature of the battery electrolyte is other then 80L F (27L C).

SPECIFIC GRAVITY

BATTERY CONDITION

 

 

1.265

100% CHARGED

1.225

75% CHARGED

1.190

50% CHARGED

1.155

25% CHARGED

1.120

DISCHARGED

Add (+) to the specific gravity reading

0.004 (4 points), for each 10L F (6L C) above 80L F (27L C) Subtract (-) from the specific gravity reading 0.004 (4 points), for each 10L F (6L C) below 80L F (27L C).

QTFSG/QTFSD 98349 05/15/03

4-14

Page 31
Image 31
Windsor QTFSD, QTFSG manual 4-14, When servicing machine, avoid contact with acid, Battery Maintenance