Maintenance schedule

Maintenance schedule

After the work

￿Warning

Risk of damage. Do not wash down the appliance with water and do not use ag- gressive detergents.

ÎEmpty the recovery tank.

ÎClean the seals between the recov- ery tank and the appliance.

ÎEmpty the solution tank.

ÎRinse the appliance: Fill the solution tank with water (without detergent) and let the appliance run for one minute with the brush water supply turned on.

ÎEmpty the solution tank.

ÎClean the outside of the appliance with a damp cloth which has been soaked in mild detergent.

ÎClean the squeegee, check for wear and replace if required (see "Mainte- nance tasks").

ÎCheck the brush for wear and re- place if required (see "Maintenance tasks").

Yearly

ÎHave the prescribed safety inspec- tion carried out by an electrician.

Maintenance Works

Replace the squeegee.

Note

The squeegee is attached to the appli- ance with snaps and can simply be pulled off.

ÎMove the squeegee lift pedal to posi- tion „suction off“ (Fig. 3 - position "1/ ON", see inside front cover).

ÎRemove the solution tank from the appliance.

ÎRemove the recovery tank.

10English

ÎLay the device down on the back- side.

ÎPull off the squeegee downwards.

ÎInsert the new squeegee and lock them into place.

Replacing the brush

ÎRemove the solution tank from the appliance.

ÎRemove the recovery tank.

ÎLay the device down on the back- side.

ÎPress the release button for the brush and swivel the brush toward the bottom and pull it off the driver.

ÎPlace the new brush on the driver and lock into place on the opposite side.

Frost protection

In case of danger of frost:

ÎEmpty the solution and recovery tank.

ÎStore the appliance in a frost-pro- tected room.

Faults

￿Danger

First pull out the plug from the mains be- fore carrying out any tasks on the ma- chine.

￿Warning

Risk of damage to the appliance on ac- count of water leakage. Empty the waste water reservoir and the fresh wa- ter reservoir prior to performing mainte- nance on the appliance.

In case of faults that cannot be reme- died using the table below please con- tact the customer service.