Image 11

Error

Remedy

 

 

Appliance cannot

Check if the mains plug is connected.

be started

 

 

 

Insufficient water

Check clean water level, refill tank if necessary.

quantity

 

Clean the water distributor (see chapter "Cleaning the water

 

 

distributor").

 

 

 

Pull off the valve on thesolution tank (Fig. 4, see inside front

 

cover) and rinse in lukewarm water.

 

 

Fresh water reser-

Pull off the valve on the solution tank (Fig. 4, see inside front

voir drips when re-

cover) and rinse in lukewarm water.

filled

 

 

 

Insufficient vacu-

Empty the solution tank.

um performance

 

Lock the recovery tank in place on the appliance.

 

 

 

 

Clean the seals between recovery tank and cover and

 

check for tightness, replace if required.

 

 

 

Check that all squeegee are locked into place in the clean-

 

ing head.

 

 

 

Squeegee worn, replace if required.

 

 

 

Check that both suction tube parts are correctly attached to

 

the suction tube connection.

 

 

 

Check the suction tube and the suction channel in the

 

cleaning head for obstruction and remove if necessary (see

 

"Cleaning suction tube").

 

 

Insufficient clean-

Check the brush for wear, replace if required.

ing result

 

 

 

Brush does not

Check if foreign matters are blocking the brush; remove for-

turn

eign matter if required.

 

 