Error | Remedy | |
|
| |
Appliance cannot | Check if the mains plug is connected. | |
be started |
| |
|
| |
Insufficient water | Check clean water level, refill tank if necessary. | |
quantity |
| |
Clean the water distributor (see chapter "Cleaning the water | ||
| ||
| distributor"). | |
|
| |
| Pull off the valve on thesolution tank (Fig. 4, see inside front | |
| cover) and rinse in lukewarm water. | |
|
| |
Fresh water reser- | Pull off the valve on the solution tank (Fig. 4, see inside front | |
voir drips when re- | cover) and rinse in lukewarm water. | |
filled |
| |
|
| |
Insufficient vacu- | Empty the solution tank. | |
um performance |
| |
Lock the recovery tank in place on the appliance. | ||
| ||
|
| |
| Clean the seals between recovery tank and cover and | |
| check for tightness, replace if required. | |
|
| |
| Check that all squeegee are locked into place in the clean- | |
| ing head. | |
|
| |
| Squeegee worn, replace if required. | |
|
| |
| Check that both suction tube parts are correctly attached to | |
| the suction tube connection. | |
|
| |
| Check the suction tube and the suction channel in the | |
| cleaning head for obstruction and remove if necessary (see | |
| "Cleaning suction tube"). | |
|
| |
Insufficient clean- | Check the brush for wear, replace if required. | |
ing result |
| |
|
| |
Brush does not | Check if foreign matters are blocking the brush; remove for- | |
turn | eign matter if required. | |
|
|
English 11