1.BRUSH SWITCH

1.BRUSH SWITCH

Controls the scrub brush motor.

To turn scrub brush on, press the top of the switch.

To turn scrub brush off, press the bottom of the switch.

2.BRUSH LIFT LEVER Raises and lowers the brush.

To lower the brush, lift the lever from the notch, move to the left, then lower.

To raise the brush, lift the lever from its lowered position.

3.VACUUM SWITCH Controls the vacuum motor.

To start vacuum motor, press the top of the switch.

To stop vacuum motor, press the bottom of the switch.

4.SQUEEGEE LIFT LEVER Raises and lowers the squeegee.

To lower the squeegee, lift and pull the lever to the left and then lower.

To raise the squeegee, lift the lever and push it to the right.

5.SOLUTION CONTROL LEVER Controls solution flow to scrub deck.

To increase flow pull and raise the knob to the desired flow.

To decrease flow push the knob down.

CONTROLS – NON TRACTION

6.BATTERY CHARGE LEVEL INDICATOR Indicates the charge level of the batteries.

The meter display is divided into 10 vertical bars. Bars illuminated on the far right indicate full charge. Bars flashing near the left side indicate the batteries should be recharged. Further operation of the machine could damage the machine or the batteries.

When the machine is left overnight with less than a full charge, the display may initially indicate a full charge. It will also indicate a full charge if the batteries are disconnected, then reconnected. After a few minutes of operation the meter will give the correct charge level.

7.HOUR METER (OPTIONAL)

Records the number of hours the machine’s brush has been in operation. This information is useful in determining when to service the machine.

8.CIRCUIT BREAKERS

Circuit breakers interrupt the flow of power in he event of an electrical overload. When a circuit breaker is tripped, reset it by pressing the exposed button. If a circuit breaker continues to trip, the cause of the electrical overload should be found and corrected.

30 Amp. Protects the scrub brush motor.

30 Amp. Protects the vacuum motor.

SABER (SC) 86038350 01/29/07