EMPTYING AND CLEANING TANKS
1.Park the machine next to a floor drain. Drain hoses are on the rear of the machine.
2.Turn the machine power off.
SOLUTION TANK
1.Unhook the small drain hose from the retainer. Unscrew the
2.Remove the solution tank cover.
3.Flush the solution tank out with clean water and run several gallons of clean water through systems. Do not use water hotter than 140°F (60°C) to clean the tank, damage may occur.
NOTE: Never allow solution to remain in tank. Damage to tank, seals and valves could occur.
4.Replace the drain plug and secure the drain hose in the bracket.
MACHINE OPERATION
RECOVERY TANK
1.Unhook the large drain hose from the retainer. Unscrew the
2.Raise the solution tank to access the recovery tank. Make sure the support arm is fully engaged. Remove the vacuum motor and rear access cover. Flush the recovery tank out with clean water. Do not use water hotter than 140°F (60°C) to clean the tank, damage may occur.
3.Clean off the float and check for free movement of the float ball. The float is attached to the bottom of the vacuum motor.
4.Replace the drain plug and secure the drain hose in the bracket.
5.If the machine is to be stored, leave solution tank in the raised position.
SABER (SC) 86038350 01/29/07 |
|
|