4. Safety devices
This steam cleaner has been fitted with various safety devices to provide multiple protection measures. The most important safety components are described below.
4.1 Pressure controller
The pressure controller maintains the boiler pressure at as constant a level as is possible while the cleaner is in use. The heater is switched off when the operating pressure inside the boiler reaches its maximum of 3.2 bar, and switched on again when the pressure drops as a result of steam being drawn off.
4.2 Low-water thermostat
As the water inside the boiler is consumed, the temperature around the heater rises. The
4.3 Safety thermostat
If the
4.4 Safety cap
The safety cap seals off the boiler and keeps the steam pressure inside. If the pressure controller becomes defective, and the pressure inside the boiler rises above 5.5 bar, an overpressure valve opens inside the safety cap, and steam escapes into the open. Contact your authorized WINDSOR Customer Service agent before using the cleaner again.
10English