Wolf Appliance Company IS15/S manual Steamer Module Operation, Timer, Automatic Drain

Models: IS15/S

1 24
Download 24 pages 10.81 Kb
Page 10
Image 10
TIMER

Steamer Module Operation

10

Steamer Module Operation

TIMER

The steamer module features a countdown timer located in the control panel. Refer to the illustration below.

The timer may be set in one-minute increments up to 99 minutes. Once set, the remaining time will be illuminated in the control panel as it counts down. The timer can be used anytime the module is not in lock mode.

tTo start the timer, touch + on the timer control. Touch and hold + or until the desired time is shown in the timer display. The timer will begin its countdown in minutes, 3 seconds after the time is set.

tA warning chime will sound when the timer has one minute left and begins to countdown in seconds.

tWhen the timer reaches 0, an audible chime will sound. The chime will continue to sound every 30 seconds until CLEAR is touched.

AUTOMATIC DRAIN

IMPORTANT NOTE: The automatic drain feature will only function if water is below 140°F (60°C). It is recommended that the steamer module be installed with a drain connec- tion and access to the drain through the base cabinet.

The DRAIN touch pad operation is functional only while the module is in idle mode. The unit must be unlocked and not in operation. Refer to the illustration below.

To activate the drain:

tTouch DRAIN for 3 seconds. An audible chime will sound, the light in the DRAIN touch pad will illuminate and the drain valve will open for a period of 2 minutes. This should be enough time to drain a full capacity of water. This operation may be repeated as many times as needed to completely drain the steamer basin.

tTouch DRAIN again while in the drain mode operation to shut the drain valve. The light in the DRAIN touch pad will go out.

+ AND

TOUCH PADS

TIMER DISPLAY

IMPORTANT NOTE: If you do not have a fixed drain connection, a heat-resistant bucket can be positioned under the drain outlet to accept the water. The bucket must have a minimum 2 gallon (7.6 L) capacity.

AUTOMATIC DRAINCAUTION

Use caution when draining hot water from the steamer basin to avoid burns.

Timer controls.

DRAIN

TOUCH PAD

Automatic drain.

Page 10
Image 10
Wolf Appliance Company IS15/S manual Steamer Module Operation, Timer, Automatic Drain, To activate the drain