Install PBY Tube Assembly

1.Remove slug on right side of backhoe console.

2.Remove plug from PBY port on right side of back- hoe valve.

3.Install Power Beyond sleeve (10), straight con- nector (12), and tube assembly (11) on the side of the backhoe valve PBY port. See Figure 16.

4.Attach female quick coupler (2) to third hose (1).

5.Connected to the PBY tube assembly (11).

1.38656 Hose, 112" x 3/8 NPTM x 3/4 ORBM

2.64299 Quick coupler, female 3/8 NPT

10.37409 Power-Beyond sleeve

11.55046 Tube assembly

12.61 Straight connector

Remove Slug

10

12

11

DP3

Figure 16. PBY Tube Assembly Installed

11

1

 

12

2

 

 

Hoses Previously

10

Installed

 

Backhoe Valve

 

PBY Port

 

Backhoe Valve

 

OUT Port

Backhoe Valve

CD5030-1

 

IN Port

Figure 17. Backhoe PBY Hose Installation