Model W1784 (Mfg. Since 2/07)
Troubleshooting
Symptom
Possible Cause
Possible Solution
Air leaking at | 1. | 1. |
whack cap area. | housing are damaged. | operation checked. |
Air leaking between | 1. Loose screws in housing. | 1. Tighten screws. |
housing and hose | 2. Damaged | 2. Replace |
| 3. Loose air fitting. | 3. Tighten air fitting & use |
|
| teflon tape. |
Air leaking between | 1. Damaged seal. | 1. Replace damaged seals. |
housing and cap. |
|
|
Tool skips staples | 1. Excessive air pressure. | 1. Reduce air pressure to tool. |
while discharging. | 2. Air leaks. | 2. Tighten screws and fittings. |
| 3. Dirt in nose. | 3. Clean nose. |
| 4. Dirt or damage prevents | 4. Clean magazine and |
| staples from moving freely. | inspect/repair damage. |
| 5. Inadequate air flow to tool. | 5. Check fittings, hose, |
|
| compressor, and air |
|
| pressure. |
| 6. Worn piston | 6. Replace |
| lubrication. | lubricate. |
| 7. Damaged plunger/cylinder O- | 7. Replace plunger/cylinder |
| rings. | |
| 8. Worn bumper. | 8. Replace bumper. |
| 9. Cap seal leaking. | 9. Replace cap seal. |
Tool runs slowly or | 1. Undersized air hose. | 1. Use a larger hose. |
has a loss of power. | 2. Stapler is not lubricated. | 2. Lubricate stapler. |
| 3. Broken spring in cap assembly. | 3. Replace spring. |
| 4. Exhaust ports on cylinder cap | 4. Clean or replace damaged |
| are blocked. | internal parts. |
Fasteners | 1. Staples are the wrong size. | 1. Use correct staples. |
frequently jam the | 2. Staples are bent or dirty. | 2. Use undamaged, clean |
stapler. |
| staples. |
| 3. Magazine or nose screws are | 3. Tighten magazine. |
| loose. |
|
| 4. Driver or driver guide are | 4. Replace worn or damaged |
| worn or damaged. | parts. |
| 5. Staples are wrong angle. | 5. Use correct angle staples. |
Stapler does not | 1. Stapler is not lubricated. | 1. Follow lubricating |
fire. |
| instructions. |
| 2. Staple is jammed in magazine | 2. Clear stapler magazine or |
| or discharge area. | discharge area. |
| 3. Piston shaft is damaged. | 3. Replace piston shaft. |
| 4. Air pressure too low. | 4. Check/increase air |
|
| pressure. |
Air blows out | 1. | 1. Reinstall/replace suspect |
of exhaust cap; | damaged inside stapler. | |
stapler will not |
| pressure. |
fire. |
|
|
|
|