Installing the inverter
975-0128-01-01 3–9
DC fuse(s) as calculated in “Calculating Fuse/Circuit Breaker Size”
on page 3–7 and fuse holder(s)
Copper chassis ground cable as calculated in Table 3-2,
“Recommended Chassis Ground Cable sizes” on page 3–6
Battery isolator (if connecting to a multiple-battery system)
Battery disconnect switch
Battery selector switch*
Alternator controller*
High-output alternator*
* Consult Appendix B, “Battery Types and Sizes” and Appendix C,
“Alternators and Charging Systems” to determine whether you need these
components.
Overview of Installation Steps
These are the five steps for installing your inverter. Do not proceed with
installation until you have read “Designing Your Installation” starting on
page 3–1.
1. Install the Remote On/Off Switch.
2. Mount the inverter.
3. Connect the AC cables.
4. Connect the chassis ground.
5. Connect the DC cables.
Installing the Remote On/Off Switch
The Remote On/Off switch can be plugged into the remote switch jack on
the front of the inverter. The remote switch lets you turn the inverter on
and off from a convenient location—up to 20 feet (6 m) away from the
inverter.
XPower3000.book Page 9 Wednesday, December 10, 2003 6:52 AM