Troubleshooting

Troubleshooting Reference

WARNING: Electrical shock and burn hazard

Do not disassemble the inverter. It does not contain any user-serviceable parts. Attempting to service the inverter yourself could result in an electrical shock or burn.

Table 5-1

Troubleshooting Reference

 

 

 

 

 

 

 

 

Error/Warning

 

 

 

#

Code on Display

Problem

Possible Cause

Solution

 

 

 

 

 

1

AL1: Flashing

Low DC input

Poor DC wiring

Use proper cable size and

 

Alarm: Beeping

terminal voltage.

 

lengths and make solid

 

 

 

 

 

connections.

 

 

 

 

Poor battery condition

Charge the battery.

 

 

 

 

 

Install a new battery.

 

 

 

 

 

2

AL2: Flashing

Inverter is close to

Inverter ventilation

Improve ventilation. Make

 

Alarm: Beeping

over-temperature

openings are obstructed.

sure the inverter’s ventilation

 

 

 

shutdown

 

openings are not obstructed.

 

 

 

 

Ambient temperature is

Reduce the ambient

 

 

 

 

too high.

temperature.

 

 

 

 

Load applied is above

Reduce the load if continuous

 

 

 

 

the continuous operation

operation is required.

 

 

 

 

limit.

 

 

 

 

 

 

3

E01: Flashing

Inverter is in

AL1 warning code is

See solution under error # “1”

 

Fault LED: Flashing

undervoltage

ignored. (See possible

in this table.

 

Alarm: Beeping

shutdown.

causes under error # “1”

 

 

 

 

 

in this table).

 

 

 

 

 

 

4

E02: Flashing

Inverter is in

High input voltage

Make sure the inverter is

 

Fault LED: Flashing

overvoltage

 

connected to a 12 V battery.

 

Alarm: Beeping

shutdown.

 

Check the voltage regulation

 

 

 

 

 

 

 

 

 

 

of the charging system.

 

 

 

 

 

 