Troubleshooting Reference

 

 

 

 

 

 

Table 5-1

Troubleshooting Reference

 

 

 

 

 

 

 

 

Error/Warning

 

 

 

#

Code on Display

Problem

Possible Cause

Solution

 

 

 

 

 

5

E03: Flashing

Inverter is in

Load applied is above

Reduce the load if continuous

 

Fault LED: Flashing

overload shutdown.

the continuous operation

operation is required.

 

Alarm: Beeping

 

limit.

 

 

 

 

 

 

6

E04: Flashing

Inverter is in

AL2 warning code is

See solution under error # “2”

 

Fault LED: Flashing

thermal shutdown.

ignored. (See possible

in this table.

 

Alarm: Beeping

 

causes under error # “2”

 

 

 

 

 

in this table).

 

 

 

 

 

 

7

E05: Flashing

Output on inverter

N/A

Remove the short circuit.

 

Fault LED: Flashing

is shortcircuit

 

 

 

Alarm: Beeping

 

 

 

 

 

 

 

 

 

8

N/A

 

Low output voltage

You are using a

Use a true RMS reading

 

 

 

(96 VAC–104 VAC)

voltmeter that cannot

voltmeter such as the Fluke

 

 

 

 

accurately read the RMS

87.

 

 

 

 

voltage of a modified

 

 

 

 

 

sine wave.

 

 

 

 

 

 

 

9

N/A

 

Low output voltage

Low input voltage and

Check the connections and

 

 

 

on a true RMS

the load is close to

cable to see if the battery is

 

 

 

reading voltmeter.

maximum allowable

fully charged. Recharge the

 

 

 

 

power.

battery if it is low.

 

 

 

 

 

Reduce the load.

 

 

 

 

 

 

10

N/A

 

No output voltage;

The inverter is off.

Turn the inverter on.

 

 

 

no input voltage

 

Check the wiring to the

 

 

 

indication.

No power to the inverter.

 

 

 

 

 

inverter.

 

 

 

 

Inverter fuse open.

Return the inverter.

 

 

 

 

The inverter could have

The inverter has probably

 

 

 

 

been connected with

been damaged. Have it

 

 

 

 

reverse DC input

repaired. Damage caused by

 

 

 

 

polarity.

reverse polarity is not covered

 

 

 

 

 

by the warranty.

 

 

 

 

Battery disconnect

Close battery disconnect

 

 

 

 

switch or breaker is off.

switch or breaker.

 

 

 

 

 

 