Battery Types

Battery

Connections to battery posts must be made with permanent connectors

Connections

that provide a reliable, low-resistance connection. Do not use alligator

 

clips. Clean the connections regularly and prevent corrosion by using a

 

protective spray coating or Vaseline.

Battery State of

You can measure battery state of charge with a hydrometer or

Charge

approximate state of charge with a voltmeter. Use a digital voltmeter that

 

can display tenths or hundredths of a volt when measuring 10 to 30 volts.

 

Make your measurements when the battery has not been charged or

 

discharged for several hours. For a deep-cycle battery at 77º F (25º C), use

 

the following table:

 

 

 

 

 

 

 

Battery Voltage

State of Charge

 

 

 

 

 

12.7–13.0 V

100%

 

 

 

 

 

 

12.5–12.6 V

80%

 

 

 

 

 

 

12.3–12.4 V

60%

 

 

 

 

 

 

12.1–12.2 V

40%

 

 

 

 

 

 

11.9–12.0 V

20%

 

 

 

 

 

B–8

975-0128-01-01

Page 54
Image 54
Xantrex Technology 3000 manual Following table