Xantrex Technology 800, 400 manual Electrical Specifications, AC Power Section

Models: 400 800

1 58
Download 58 pages 21.2 Kb
Page 52
Image 52
Electrical Specifications

Electrical Specifications

AC Power Section

 

Output power

 

 

 

• Continuous output power

 

160 W

 

• Five minute AC output power

 

200 W

 

• AC output surge capacity

 

320 W

 

 

 

 

 

Output voltage

 

115 ± 10 V AC RMS

 

 

 

 

 

Output frequency

 

60 Hz ± 1 Hz

 

 

 

 

 

Output wave form

 

modified sinewave

 

 

 

 

 

No load current draw

 

<0.20 A DC

 

 

 

 

 

Input voltage range

 

10.5 to 15.5 V DC

 

 

 

 

 

Low battery alarm

 

11.0 V DC

 

 

 

 

 

Low battery shutdown

 

10.5 V DC

 

 

 

 

 

High battery voltage shutdown

 

Yes, automatic reset

 

 

 

 

 

Over temperature shutdown

 

Yes, automatic reset

 

 

 

 

 

Overload shutdown

 

Yes, automatic reset

 

 

 

 

 

AC output short circuit protection

 

Yes, automatic reset

 

 

 

 

 

Fuse (internal)

 

25 A

 

 

 

 

 

Operating temperature range

 

0–40ºC

 

 

 

(32–104ºF)

 

 

 

 

 

Storage temperature range

 

0–30ºC

 

 

 

(32–86ºF)

 

 

 

 

 

 

 

 

 

Internal Battery Charging Controller System

 

 

 

 

 

AC Charger bulk charging current

 

500 mA

 

 

 

 

 

Peak charging voltage (nominal)

 

14.2 V

 

 

 

 

 

Charge restart voltage (nominal)

 

12.9 V

 

 

 

 

 

Float charge after full charge is completed

 

1 mA

 

(nominal)

 

 

 

 

 

 

 

AC Charger input socket maximum current

 

2.5 A

 

 

 

 

 

 

 

 